XSci

Missed Detections and False Alarms in a CNN Technosignature Detector on Breakthrough Listen Data

Omer Imran

Submitted by Omer Imran

Published October 19, 2026 · Version v1, October 19, 2026 · DOI 10.66977/xsci.2610.001s

Astrophysics

Abstract

Radio technosignature searches rely on machine learning detectors to shrink the candidate pool before a human looks at it. They are validated on held-out data from the training distribution, which excludes the cases where they are most likely to fail: a technosignature has unknown morphology, and terrestrial interference is unbounded in variety. I trained a standard competition detector once, froze it, and probed it with 15,000 injections across ten morphologies and five amplitudes, placed into real Green Bank backgrounds. Two directions were tested: genuine signals with morphologies other than a straight narrowband line, and interference resembling the training data. Recall did not follow the predicted ordering, and it fell as signals brightened, even for a needle of the kind the detector was trained on (from 0.590 to 0.090). One interference morphology reached a false positive rate of 0.627, comparable to the detector's own baseline recall of 0.5525 on genuine signals. Gradient-weighted Class Activation Mapping (Grad-CAM) showed attention along the injected path in one missed family by a pre-specified test, and visually in a second. A pre-specified, time-averaged ON-OFF filter removed false alarms and genuine detections at the same rate. The detector reads only the ON panels. Since the only evidence distinguishing a genuine candidate from terrestrial interference lies in the discarded OFF panels, it cannot tell if a signal originates from the target star; it can only tell if it resembles the training data. This explains the false alarm directly; the missed signals reflect what the detector learned to recognise, which reading the OFF panels would not by itself change.

View PDF

Review reports

Reviewer3 (AI review)

October 19, 2026

AI Review (reviewer3.com)

Comments (5)

1. D1-5 shape description conflicts with fixed-form statement — Editorial

lines, drifting 60 and 45 frequency channels across a panel respectively. The starting channel of each injection was drawn at random between channels 64 and 192 and recorded in the manifest, and the parameters of each family are given in Table 1.

In Section 3.3 (page 5), the paper states that for every injection, "The starting channel of each injection was drawn at random between channels 64 and 192 and recorded in the manifest, and the parameters of each family are given in Table 1." However, in Table 1 (page 4), D1-5 (dispersed burst) is defined across all channels as "broadband; arrival at sample 30 + 180(f/256)², σ = 6 samples", and in Section 6 (page 15), the paper states that "D1-5 paths, which share one fixed curved form and overlap, so its ratio is biased towards 1.0". A broadband curve with a single fixed arrival-time formula across all 256 channels cannot simultaneously have a random starting channel drawn between 64 and 192.

2. Filter definition conflates signal amplitude with signal energy — Major

The filter measures ON-OFF contrast, the difference in energy between the ON and OFF panels (Figure 4). Precisely, it averages each frequency channel over time and over the three ON panels, does the same for the three OFF panels, subtracts the two profiles, smooths the result over 9 channels, and takes its maximum, S.

In Section 3.6, the cadence filter is described as measuring the difference in energy between the ON and OFF panels by averaging each frequency channel over time and over the three panels. However, as established in Section 3.3, the competition spectrograms are already normalized to approximately zero mean and unit standard deviation, and the synthetic signals were injected as linear amplitudes (in units of background standard deviation) rather than squared intensities. A linear average of zero-mean normalized spectrogram values measures amplitude contrast rather than energy, and any zero-mean oscillatory or noise-like component will cancel unless squared or rectified prior to averaging. The author should clarify the exact mathematical formula for the statistic S (whether it averages raw values or squared values) and revise the terminology so amplitude and energy are not conflated.

3. Unspecified Grad-CAM target output, sign handling, and erasure values — Major

To isolate the effects of injection in the image, I first computed the heatmap for a clean image, then the same image with an injection, and subtracted. The background therefore cancels, and what remains is exactly what the injection changed. I used two measures on this difference map. The first is its total magnitude, the sum of its absolute values,

The manuscript states that a custom Grad-CAM implementation was used to compute difference maps (injected minus clean) and that top-ranked regions were erased to test causality. However, key mathematical and procedural details of these definitions are omitted: it is unclear whether gradients were taken with respect to the pre-sigmoid logit or the post-sigmoid probability, whether the standard ReLU nonlinearity was applied to individual heatmaps before subtraction, whether region ranking for the deletion test used positive or signed/absolute difference values, and what replacement value (e.g., zero, local mean, or clean background pixels) was substituted during erasure. Because the interpretation in Section 5.3—that the model actively weighed missed signals against a detection—depends on why erasing top-ranked Grad-CAM cells raised the model score, the reader cannot tell if this score increase stems from removing negatively weighted features or from an artefact of the erasure replacement value itself. The author should explicitly specify the Grad-CAM equations, sign conventions, and pixel-erasure baseline in Section 3.5.

4. Extreme score selection in D1-1 misses confounds erasure test — Major

an amplitude of 0.5. Q2_bright_hit is the twelve highest-scoring detections of D1-3, and Q2c_bright_mis the twelve lowest-scoring misses of D1-1, both at an amplitude of 4.0. Q3_pulsed and Q3_dispersed are twelve injections of D1-4 and D1-5 drawn at random with a fixed seed, at an amplitude of 4.0. The heatmap shows where the model looked but not if it is causal. Hence, I erased the region Grad-CAM

The author concludes that the detector registered bright D1-1 signals and weighed parts of them against a detection because erasing the highest-ranked Grad-CAM regions raised the model score more than erasing random regions in 10 of 12 samples. However, the Q2c_bright_mis cohort was constructed by selecting the 12 lowest-scoring misses of D1-1 out of 300 injections at amplitude 4.0 (unlike Q3_pulsed and Q3_dispersed, which were drawn at random). Selecting the extreme lower tail of the score distribution introduces a strong regression-to-the-mean bias and specifically isolates instances where the interaction between the injected line and background suppressed the output score, even though in 94% of all 300 D1-1 injections at amplitude 4.0 the injection actually increased the score above the clean background. The author should either repeat the D1-1 deletion test on a randomly drawn cohort of misses or explicitly caveat that the negative-weighting result in Q2c_bright_mis may be an artefact of selecting the 12 lowest-scoring samples.

5. Pooled filter retention and AUC are confounded by amplitude — Major

To identify why, I measured the ON-OFF asymmetry present in real backgrounds. The median ON-OFF asymmetry was 0.185 in 300 clean backgrounds and 0.228 in 1,775 flagged genuine signals, so a genuine signal shifts the statistic by only about 0.04 (Figure 11), largely because the time averaging described in Section 3.6 dilutes a drifting line before the comparison.

The manuscript reports that across all families and amplitudes the cadence filter retained only 25 of 1,775 genuine detections (1.4%) and achieved an ROC AUC of 0.60 when separating those 1,775 flagged genuine signals from D2-5 false alarms, concluding that a genuine signal shifts the statistic S by only about 0.04 (from a median of 0.185 in clean backgrounds to 0.228). However, pooling all 1,775 genuine detections mixes injections across a 16-fold range of amplitudes (0.25 to 4.0) and across morphologies with different drift widths, while D2-5 false alarms are concentrated at amplitudes 0.25–1.0. Because the analytical signal contribution to S scales linearly with injected amplitude A and inversely with drift width D (and 9 smoothing channels), an S shift of ~0.04 is expected at faint amplitudes (0.25–0.5) where background asymmetry (median 0.185, 99th percentile 1.0266) dominates, but at amplitude 4.0 a 50-channel S-shaped signal (D1-3, which makes up 57% of the detections) should contribute ~0.24 to S—six times larger than the pooled median shift. The author should report the median S, retention rate, and ROC AUC stratified by amplitude and family, and clarify why high-amplitude D1-3 detections still fail to cross the 1.0266 threshold.

xPeerd (AI review)

October 19, 2026

AI Review (xPeerd — DAReview)

Summary

This manuscript examines failure modes of an ON-only CNN technosignature detector trained on Breakthrough Listen Kaggle data. The paper’s central contribution is a controlled stress test of a frozen detector using 15,000 synthetic injections spanning ten morphologies and five amplitudes in real Green Bank backgrounds. The main strengths are the clarity of the research question, the use of pre-specified thresholds and filter criteria, the pairing of injected samples with clean backgrounds, and the explicit separation between missed detections and false alarms. The manuscript is also commendably transparent about several limitations, including single-seed training, synthetic injections, shared backgrounds, and an unexplained brightness effect.

The main weaknesses concern external validity, causal attribution, and reproducibility claims. Several key conclusions are persuasive but not fully demonstrated experimentally, especially the claim that ON-only input explains the false alarms, the interpretation of Grad-CAM evidence, and the operational significance of a single training run. Some design choices also make the study vulnerable to confounding, including reuse of mostly seen-in-training backgrounds and non-renormalized injections. The manuscript is interesting, coherent, and aligned with an accepted scientific paradigm in machine learning robustness and technosignature search. I do not see strong paper-mill indicators; however, the acknowledgements disclose LLM assistance, so the prose should be checked carefully for over-smoothing or imprecision relative to the actual evidence.

Potential Major Revisions

  1. Strengthen the causal claim that ON-only input explains the false alarms

A central interpretive claim is: “The detector reads only the ON panels. The single property that separates a genuine candidate from terrestrial interference is presence in OFF panels, and that information is discarded before the model sees the input.” The manuscript then concludes: “The model therefore cannot be asking whether a signal originates from the target star; it can only ask whether the signal matches the learned shape.” This is plausible and likely correct, but in its current form it is still an inference from architecture rather than a direct comparative test.

The limitations section explicitly concedes this gap: “the claim that the missed signals do not depend on the OFF panels, while the false alarms do, follows from the input design but was not tested against a detector that reads all six panels.” That admission is important, but it also means the conclusion should be more carefully delimited throughout the Discussion and Conclusion. At present, the manuscript sometimes moves from “consistent with” to “explains” too quickly. A stronger revision would either temper the wording or add a direct comparator model using all six panels, even if only as a limited ablation.

  1. Address confounding introduced by the injection protocol and background reuse

The methodology is reproducible in a narrow computational sense, but some choices complicate interpretation. The paper states: “All 15,000 injections used the same 300 backgrounds, drawn from signal-free samples in the competition’s training set, about four in five of which come from the folds the detector was trained on; the same 300 backgrounds also served as the clean controls.” This may bias results in either direction. Because backgrounds were “mostly seen in training,” failures and successes are not being tested against strongly novel backgrounds. That weakens claims about out-of-distribution robustness, especially when the paper frames the study as probing behavior “outside that distribution.”

A second confound is the departure from competition preprocessing: “the competition normalised each sample after injecting its signals, whereas my injections were added to already-normalised backgrounds and not renormalised.” The paper itself acknowledges that this may explain the amplitude effect and suggests renormalization as a direct test. Because one of the headline findings is that recall falls as signals brighten, this control is not optional; it is pivotal. Without it, one of the manuscript’s most striking conclusions remains underdetermined.

  1. Reframe the brightness-effect result as provisional unless experimentally resolved

The manuscript reports a striking non-monotonic result: “the calibration needle, of the kind the detector was trained on, dropped from a recall of 0.590 at an amplitude of 0.5 to 0.090 at 4.0.” This is potentially important, but also surprising enough that it requires stronger diagnostic validation before being elevated to a main take-home message. The paper notes two untested hypotheses: mismatch caused by missing post-injection renormalization, or learned association of brightness with interference.

Because the current manuscript does not distinguish between these explanations, the finding is descriptive rather than mechanistic. I think the paper should either add the renormalized control experiment or reduce the forcefulness of claims about what this phenomenon means. At minimum, the abstract and conclusion should emphasize that the decline is robust in the present setup but causally unresolved. As written, readers may overgeneralize from a result that may partially reflect preprocessing mismatch.

  1. Clarify what “outside the training distribution” means in this study

The paper’s framing is conceptually strong, but its terminology risks overstatement. It claims to test failures beyond held-out validation and distributional assumptions, yet the backgrounds come from the competition data, the detector architecture follows the public baseline, and the morphologies are synthetic and investigator-defined.

This is still valuable, but it is more accurate to describe the work as a controlled morphology-shift and interference-shape stress test within the competition’s observational substrate, not a broad evaluation of real deployment distribution shift. The manuscript itself is careful in places, especially when it says “a real technosignature or a new kind of interference could look like none of them.” That caution should be moved closer to the paper’s core claims, including the abstract and introductory framing.

  1. Temper the evidential weight assigned to Grad-CAM and deletion tests

The attention analysis is thoughtful and unusually careful for this genre, especially because the manuscript includes a randomization check and admits weaknesses in the on-path test. Still, some inferential steps remain fragile. For D1-1, the paper states: “the CAM difference shows attention along the injected line. This reading is visual: the on-path test was inconclusive.” For D1-4 and D1-5, the authors also note that the “in-band CAM ratio was intended as evidence that the model ignores certain signals, but was retired during this analysis.”

This is honest, but it means the Grad-CAM section should be presented more as suggestive mechanistic evidence than as a settled diagnosis. The deletion test also did not meet its own pre-specified criterion “for any detected group.” The revision needed here is mostly rhetorical and structural: separate what was pre-specified and supported from what was post-hoc and illustrative, and reduce any impression that the saliency analysis independently proves the proposed mechanism.

  1. Expand robustness analysis across retraining seeds and folds

The manuscript openly states: “The detector was trained once, with one random seed and one validation fold, so the failures reported here belong to that training run; whether they persist across retraining was not tested.” This is an important limitation because the paper draws fairly general lessons about what such detectors learn. A single run can reveal a serious failure mode, but it cannot establish prevalence. Some effects may be stable architectural consequences; others may be contingent artifacts of one optimization path.

I would regard multi-seed retraining and at least limited fold variation as a major revision priority. Even a compact stability table for the headline outcomes would materially improve confidence: D2-5 false-positive behavior, D1-1/D1-2 amplitude decline, D1-4/D1-5 near-control recall, and filter retention failure.

  1. Reassess the post-hoc cadence filter claims with a path-aware baseline

The manuscript concludes that the tested “time-averaged ON-OFF statistic fails,” and it clearly states that this does not imply all post-hoc cadence checks must fail. That distinction is scientifically responsible. However, because the filter is intentionally time-averaged, and the paper itself notes that this design “made it insensitive to drifting signals by design,” the negative result is narrower than the prominence given to it may suggest.

A stronger revision would either add the path-aware comparison proposed by the author — “a path-aware comparison, which integrates along the signal’s drift before comparing ON and OFF as de-Doppler pipelines do” — or further de-emphasize the filter as a substantive contribution. In its current form, the filter result is still useful, but mainly as a cautionary failed baseline.

Potential Minor Revisions

  1. Writing and phrasing refinements

The prose is generally clear and stronger than average, but a few formulations could be tightened to avoid overstating certainty.

  • In Section 5.1, “This explains the false alarm directly” is stronger than the evidence strictly warrants given the absence of a six-panel comparator. “This provides a direct architectural explanation consistent with the false alarms observed” would be more precise.
  • In Section 5.2, “The detector rejects D2-1, but it cannot be rejecting it for being stationary, since it has no access to that reasoning” is logically sound, but “reasoning” anthropomorphizes the model. A more technical wording would help.
  • In Section 5.3, “registered but under-weighted” is memorable but slightly informal relative to the rest of the paper. Consider defining it more formally in terms of score perturbation and attribution evidence.
  • In Section 6, “which makes the absence of attention to D1-5 the least certain result in this paper” is admirably candid, but “least certain” could be replaced with a more technical description of inferential weakness.
  1. Statistical reporting and uncertainty
  • Several comparisons are described narratively without always foregrounding effect size interpretation. For example, the D2-5 peak false-positive rate is said to be nominally above baseline recall but not significant after selection correction. This is good, but the abstract should reflect the more cautious language used later.
  • The threshold is set using the same validation fold used for model selection, and the paper notes that this makes AUC and threshold “slightly optimistic.” This deserves slightly stronger prominence in Methods and perhaps Discussion because operational threshold selection is a key part of the story.
  • For the Grad-CAM analyses, n = 12 per group is small. The manuscript acknowledges this. Still, confidence intervals or bootstrap summaries for some saliency-derived quantities could help readers interpret stability.
  1. Formatting and presentation
  • The appendix table is valuable, but key headline values from Table 2 should appear in the main text or a condensed main-text table, because they support the paper’s central claims. The present structure requires readers to integrate Figure 5, Figure 6, Figure 7, and Appendix Table 2.
  • The paper sometimes relies heavily on figure interpretation for mechanistic arguments. For instance, the D1-1 attention claim is acknowledged as visual. A slightly more explicit captioning strategy would help.
  • The phrase “real needles” in Figure 7 is noted as a competition-label artifact because those signals are synthetic; this is good, but such terminology may confuse readers and could be standardized.
  1. Typographic and grammatical issues

I did not identify a large number of obvious typographic errors in the retrieved text, but a few small issues deserve correction:

  • “Data used is sourced from a Kaggle competition” would read more smoothly as “The data are sourced from” or “The data used are sourced from.” Section 3.1, page 3.
  • “the same family of post-hoc correction, but it uses the cadence structure” is understandable but stylistically slightly awkward; “the same family of post-hoc corrections” may be better. Page 2.
  • “To interpret a model’s confidence into an either yes or no” is slightly unidiomatic; “To convert the model’s confidence into a binary decision” would be cleaner. Section 3.4, page 7/8 area from snippet.
  • “Data and code availability” section is appropriate, but ensure URL line breaking does not impair readability in the final typeset version.
  1. AI content analysis for this post-2021 manuscript

Estimated percentage of AI-generated or AI-assisted prose: low to moderate, approximately 10–25%.

Basis for estimate:

  • The acknowledgements explicitly state: “I used Claude (Anthropic) as an assistant during this project: to help debug code, revise a few portions of the text, and review the manuscript.”
  • The prose is unusually polished, consistent, and rhetorically controlled, but it also contains domain-specific nuance, methodological self-critique, and locally idiosyncratic formulations that argue against full-text AI generation.
  • The manuscript includes candid self-limitations and non-generic technical specificity, which lower the probability of heavy AI drafting.

Highlighted possibly AI-assisted sections:

  • The Abstract has a compressed, highly balanced rhetorical structure that may have been AI-polished, especially sentences such as: “The detector reads only the ON panels. Since the only evidence distinguishing a genuine candidate from terrestrial interference lies in the discarded OFF panels, it cannot tell if a signal originates from the target star; it can only tell if it resembles the training data.”
  • The Discussion and Conclusion sections contain polished contrastive phrasing and well-shaped argumentative transitions that may reflect revision assistance rather than initial authorship. Examples include: “Matching on appearance rather than on the property that defines the label is an instance of what Geirhos et al. (2020) call shortcut learning.” and “The false alarms follow from one design choice: the detector reads only the ON panels, so it can judge how a signal looks but not where it comes from.”

Assessed epistemic impact:

  • Low if the disclosed use is accurate. The likely role appears editorial and diagnostic rather than substituting for the core scientific contribution.
  • The main epistemic risk is not covert AI authorship but over-clarification of arguments whose empirical support remains incomplete. In other words, the prose may sound slightly more conclusive than the evidence warrants in some places.
  • Because the author disclosed AI assistance, this is not itself a research-integrity concern. The relevant review issue is whether the polished language outruns the demonstrated evidence in Discussion and Conclusion.

Recommendations

  1. Add one decisive control experiment: repeat the amplitude analysis with post-injection renormalization matching the competition pipeline. This is the fastest way to resolve a major uncertainty behind the brightness effect.

  2. Add a six-panel comparator or, if computationally infeasible, reduce the strength of claims about what OFF-panel access would solve. Right now, the architecture strongly suggests the interpretation, but the manuscript often writes as though this has been experimentally established.

  3. Run at least limited multi-seed retraining. Even 3–5 seeds would substantially improve the manuscript’s authority on whether the identified failures are robust.

  4. Separate more sharply between:

  • demonstrated findings,
  • plausible architectural explanations,
  • and conjectural mechanisms. This would improve epistemic discipline without weakening the contribution.
  1. Reframe the study as a controlled stress test under morphology shift and cadence-information ablation, rather than a broad claim about real technosignature detection in the wild. That framing is both accurate and still impactful.

  2. Preserve the manuscript’s current strengths: its transparency, pre-specification, paired-control logic, and willingness to report negative results. These features materially improve credibility and should remain central in revision.

Overall, I judge the manuscript to be coherent, methodologically serious, and potentially publishable after substantial revision. Its core idea is worthwhile and the reported failure modes are important, but several headline conclusions need stronger experimental support or more careful delimitation before the paper is fully convincing.

XSci (AI review)

October 19, 2026

Summary

Machine-learning detectors shrink the candidate pool in radio technosignature searches, and are validated on held-out data from the distribution they were trained on, which excludes the cases where they are most likely to fail. The authors measure the cost: a public Kaggle competition baseline is trained once, frozen, and probed with 15,000 injections across ten morphologies and five amplitudes placed into real Green Bank backgrounds, at a threshold fixed beforehand. Recall does not follow the predicted ordering and falls as signals brighten, including for a needle of the familiar kind (0.590 to 0.090); one interference family reaches a false positive rate of 0.627 against a baseline recall of 0.5525; and a pre-specified ON-OFF filter removes genuine detections and false alarms at the same rate. The false alarms are attributed to the ON-only input design.

Contribution and Significance

The usable contribution is Table 2 together with Section 4.4: a complete morphology-by-amplitude completeness grid for an ML cadence detector, with Wilson intervals, a pre-registered threshold and a released injection manifest, plus a diagnosed negative result on a post-hoc cadence veto. The filter result is the stronger of the two. Section 5.4 explains why the veto failed — time-averaging dilution, background ON-OFF asymmetry (median 0.185 against 0.228 in flagged genuine signals) and a separation AUC of 0.60 — and concludes correctly that no threshold would work and that the failure belongs to a time-averaged statistic, not to cadence checks in general.

What is genuinely new is narrower than the framing suggests. That a supervised detector trained on one synthetic generator misses morphologies outside it is the stated motivation of Ma et al. (2023); the novelty here is the measurement, not the phenomenon. The central explanatory claim is weaker still: that an ON-only detector cannot judge whether a signal came from the target star follows from the input specification and needs no experiment, and the audited model is a competition baseline that no operational search deploys. Section 2 scopes this honestly; the title, abstract and conclusion do not.

Strengths

  • The decision rules are fixed in advance: the threshold at 0.1309 before any injected data was scored (Section 3.4), the filter's two success criteria (Section 3.6), and the 72-sample Grad-CAM cohort and on-path bar of 1.3 (Section 3.5).
  • The authors report against those rules when they fail: Section 4.3 states that the deletion test "did not meet its pre-specified criterion for any detected group" and retires the in-band CAM ratio as invalid; Section 3.6 discloses a discarded earlier filter.
  • Section 4.2 withdraws its own nominally significant result, correcting p = 0.018 for 0.627 against 0.5525 to p ≈ 0.09 once selection over five amplitudes is accounted for.
  • The arithmetic holds throughout: the Table 2 rates sum to the 1,775 and 502 detections of Section 4.4 and the 2,277 of Section 3.6, and the 57% share in Figure 11 and the Wilson intervals reproduce.

Recommendation

Major Revision for The Astronomical Journal. The measurements are sound, reproducible and unusually disciplined, and the cadence-filter result stands as reported; but the most striking finding, the fall in recall with brightness, is plausibly an artefact of the injection procedure, and Direction 2 is determined by the design rather than measured. Each repair below sits inside the authors' own approach and is cheap. The revision should also rescope the title, abstract and conclusion to the baseline actually audited.

Major Concerns

  1. The fall in recall with brightness is not shown to be a property of the detector (Sections 3.3, 4.1, 6; Table 2). The calibration needle, described as "of the kind in the training data", drops from a recall of 0.590 at amplitude 0.5 to 0.090 at 4.0, and D1-1, D1-2 and D2-5 all peak at 0.5 and collapse by 4.0. Section 3.3 records that the competition normalised each sample after injecting its signals, whereas these injections were added to already-normalised backgrounds and not renormalised. A procedure that loses an in-distribution morphology when it is injected brightly is at least as consistent with a mismatch between the injection pipeline and the competition's generator as with anything the detector learned.

    Section 6 names the test ("Renormalising each injected sample before scoring would test the first") but does not run it, although it needs only a rescoring pass against the frozen weights. The amplitude axis also carries the operational conclusion of Section 5.5, the shape of the D2-5 curve, and the Q2c and Q3 attention cohorts, all taken at amplitude 4.0. Please run that rescoring, extend the grid beyond amplitude 4.0, and check whether the competition's own labelled positives behave the same way when rescaled.

  2. Direction 2 measures morphology, not origin, and does so by construction (Sections 3.3, 4.2, 5.1, 6). Section 3.3 states the position exactly: "to the detector, a Direction 2 injection differs from a Direction 1 injection only in shape." The false positive rate of 0.627 is therefore the detection rate for a 45-channel drifting straight line, measurable entirely within Direction 1; the label "interference" is conferred through panels the model never sees. The conclusion that the detector "cannot tell if a signal originates from the target star" is likewise read off the input specification, and Section 6 concedes that the six-panel counterfactual was not tested.

    Evidence not fixed by the design is available in the same data: the competition cadences contain real interference, visible in all six panels of Figure 1, and scoring a set of those would measure how often the detector flags interference the authors did not place there. Training the six-panel detector named in Section 6 would serve equally. Until one is done, Direction 2 should be presented as a second slice of the morphology grid, and the comparison of 0.627 with the 0.5525 baseline dropped as not like-for-like.

  3. The causal leg of the attention analysis failed its pre-specified criterion, and the procedure is unspecified (Sections 3.5, 4.3, 5.3). The criterion was that erasing the three highest-ranked regions remove at least half the gap in at least 9 of 12 samples; Section 4.3 reports 3, 4 and 7 of 12. The figures the manuscript then relies on (0.85, 0.68 and 0.75) come from a post-hoc six-region variant, and the missed-group result that carries Section 5.3 — erasure raising the score in 10 of 12 samples — had no pre-specified criterion at all, while D1-1's on-path test was inconclusive (1.06, p = 0.18). The erasure itself is never defined — neither the region size nor the value replacing the erased pixels — so the test cannot be reproduced. The missed groups were also taken at amplitude 4.0, where erasing the on-path region removes the bright injection, so a rise in score is what Concern 1 predicts anyway. Please specify the erasure, label the claim that the detector "registered these signals and weighed parts of them against a detection" as exploratory, and repeat the test at amplitude 0.5.

Minor Comments

  1. In Section 3.6, 1.2√(2π/D) evaluates to 0.39 at D = 60, not the quoted 0.05; the intended expression appears to be 1.2√(2π)/D.
  2. Section 3.3 should say why a bespoke injector was used rather than the field's standard framework, which is uncited: Brzycki, B., Siemion, A. P. V., de Pater, I., et al. 2022, "setigen: Simulating Radio Technosignatures for the Search for Extraterrestrial Intelligence", AJ, 163, 222.
  3. Section 2 implies retention cost is checked only by Zhao et al., but Choza, C., Bautista, D., Croft, S., et al. 2024, "The Breakthrough Listen Search for Intelligent Life: Technosignature Search of 97 Nearby Galaxies", AJ, 167, 10, also characterises sensitivity by injection and recovery.
  4. Retraining with three to five seeds is inexpensive here and would show whether the failures belong to the recipe or to the single run of Section 3.2.
  5. The 300 backgrounds serve as injection substrate, clean controls and filter calibration set, and four in five come from training folds (Section 3.3); repeat with held-out-fold backgrounds.
  6. The Wilson intervals in Table 2 treat each cell's 300 injections as independent, but the same backgrounds recur in every cell, so family and amplitude comparisons are paired.
  7. Because each ON panel repeats the same path (Section 3.3), D1-3 alone is continuous across panel boundaries while D1-1 and D1-2 reset by 60 channels at each — an alternative explanation for the ordering in Section 4.1 that a cadence-continuous injection would test.
  8. The twelve lowest-scoring D1-1 misses all start between channels 165 and 191 (Section 4.3), the top quarter of the 64-to-192 draw range, so recall against starting channel should be reported.
  9. The checkpoint was selected by best AUC on fold 0, and the threshold, the AUC of 0.8545 and the baseline recall of 0.5525 come from that same fold (Sections 3.2, 3.4); quantify the optimism elsewhere.
  10. The path-aware comparison of Section 5.4, free given the manifest, should accompany the negative result, since Section 3.6 predicts the filter's insensitivity before it is run.
  11. The needle calibration is reported only at amplitudes 0.5 and 4.0 and at n = 100 rather than 300 (Section 3.3), although the amplitude scale rests on it.
  12. Several sentence openings are corrupted ("10 tnd the reason", Section 3.5; "1ne statistic also barely separates", Section 4.4), and the Q1 deletion figures 0.85 and 0.68 appear twice in Section 4.3.