XSci

EFFECT OF UNSM MODES 10F, 20F AND 30F ON THE STRUCTURE AND PROPERTIES OF THE SURFACE LAYER OF 45 STEEL

Kaliaskarova Moldir

Submitted by Kaliaskarova Moldir

Published October 21, 2026 · Version v1, October 21, 2026 · DOI 10.66977/xsci.2610.0024

Particle Physics

Abstract

Ultrasonic nanocrystal surface modification (UNSM) in the 20F mode gave the best surface of 45 steel among the three modes studied: instrumented hardness HIT rose from 3962 to 5319 N/mm² (+34.2%), Vickers hardness from 587 to 694 HV, Ra fell from 0.034 to 0.020 μm, and the friction coefficient dropped from 0.712 to 0.574. Three UNSM modes (10F, 20F, 30F), each defined by static load, amplitude, feed rate and pass step, were compared with the as-received state by scanning electron microscopy, X-ray diffraction, instrumented and Vickers indentation, profilometry and ball-on-disk tests. All modes formed a layer of refined grains under the surface, and its depth grew with the treatment intensity. Raising the intensity from 20F to 30F did not improve the properties: hardness fell by 2.2%, and Ra and the friction coefficient rose, which may be associated with saturation of strain hardening and the onset of surface damage. The 20F mode is the most favourable of the three modes for hardening 45 steel.

View PDF

Review reports

Reviewer3 (AI review)

October 21, 2026

AI Review (reviewer3.com)

Comments (15)

1. In-text description of Reference [6] contradicts bibliography entry — Editorial

Studies on AISI 1045 steel, which has a chemical composition similar

In Section 1, Reference [6] is cited as a study on AISI 1045 steel investigating microhardness, wear resistance, and surface microfeatures acting as micro-reservoirs. However, in the References section on page 6, entry [6] is titled "Effect of Ultrasonic Nanocrystalline Surface Modification on Hardness and Elastic Modulus of Ti-6Al-4V Alloy", which is a study on a titanium alloy rather than AISI 1045 steel. (Additionally, References [7] and [9] appear in the reference list but are never cited in the text.)

2. Figure 2b contradicts peak intensity and shift claims — Major

new phases. The change is in peak shape near 2θ ≈ 43 – 44°: the peaks broaden, lose intensity and shift slightly to higher angles. This indicates grain refinement, higher lattice micr ostrain and residual compressive stress. The changes are strongest in the 20F mode.

Section 3.2 states that for the diffraction peaks near 2θ ≈ 43–44°, "the peaks broaden, lose intensity and shift slightly to higher angles... The changes are strongest in the 20F mode." However, Figure 2b shows the opposite for both intensity and peak shift: (1) the 20F peak has the highest intensity of all curves (~1450 a.u. absolute maximum, or ~1100 a.u. above its ~350 a.u. baseline), which is higher than the Initial state (~1080 a.u. maximum, or ~1030 a.u. above its ~50 a.u. baseline) rather than losing intensity; (2) the 10F peak shifts to a lower angle (~43.5°) relative to the Initial peak (~43.7°) rather than to a higher angle; and (3) the largest shift to higher angles occurs in the 30F mode (~44.2°), not the 20F mode (~43.9°).

3. Missing profilometry scan parameters and measurement orientation — Major

The surface roughness parameters were determined using an SSR - 300 profilometer (Shenzhen, Guangdong, China). The Ra and Rz parameters were calculated from the obtained mea surement data.

While the authors report Ra and Rz values down to 0.020 μm (20 nm) using an SSR-300 contact profilometer, they do not specify the evaluation length, cut-off filter wavelength (λc), stylus tip radius, or the measurement direction relative to the UNSM scanning passes. Because UNSM creates directional grooves governed by the feed direction and pass step (50–90 μm), roughness measured parallel versus perpendicular to the treatment tracks differs substantially. The authors should report the profilometry cut-off and traversal parameters and specify the orientation of the 10 measurements relative to the UNSM feed direction.

4. Contradiction between text and Figure 2b on peak intensity — Minor

new phases. The change is in peak shape near 2θ ≈ 43 – 44°: the peaks broaden, lose intensity and shift slightly to higher angles. This indicates grain refinement, higher lattice micr ostrain and residual compressive stress. The changes are strongest in the 20F mode.

The text states that after UNSM the diffraction peaks near 2θ ≈ 43–44° broaden and lose intensity, with the strongest changes occurring in the 20F mode. However, inspection of Figure 2b shows the opposite for peak intensity: the 20F curve (red) has the highest peak maximum (~1480 a.u.) and largest integrated area, substantially exceeding the Initial state (~1150 a.u.), 30F (~1200 a.u.), and 10F (~1020 a.u.), and the 20F peak does not appear broader than the 10F or Initial peaks. The authors should reconcile this contradiction between the plotted diffractograms in Figure 2b and the text description, and explain why the peak intensity increases in the 20F and 30F modes (e.g., preferred orientation/texture development).

5. Absence of quantitative XRD peak fitting for broadening and shift — Minor

new phases. The change is in peak shape near 2θ ≈ 43 – 44°: the peaks broaden, lose intensity and shift slightly to higher angles. This indicates grain refinement, higher lattice micr ostrain and residual compressive stress. The changes are strongest in the 20F mode.

The claim that XRD peaks near 2θ ≈ 43–44° broaden, lose intensity, and shift to higher angles—and that these changes are strongest in the 20F mode—is asserted without reporting numerical peak positions, full width at half maximum (FWHM) values, integrated intensities, or crystallite size/microstrain calculations. Quantitative peak fitting (e.g., pseudo-Voigt or Lorentzian fitting to extract exact 2θ centroids and FWHM values) is necessary to objectively compare the four states.

6. No direct measurement of surface damage in 30F mode — Major

→ 672 HV), so the two methods agree despite their different absolute values. The 2.2% drop from 20F to 30F reflects saturation of strain hardening and the accumulation of local defects: more energy no longer refines the grains, it damages the layer.

The authors attribute the slight decrease in hardness and increase in roughness and friction in the 30F mode to the accumulation of local defects and the onset of surface damage. However, no top-view SEM micrographs, 3D surface topographies, or crack/spallation observations of the treated surfaces are presented, and the 30F surface is actually smoother (Ra = 0.023 μm, Rz = 0.386 μm) than both the initial surface (Ra = 0.034 μm, Rz = 0.562 μm) and the 10F surface (Ra = 0.027 μm, Rz = 0.447 μm). To substantiate the claim of surface damage in the 30F mode, the authors should provide top-surface SEM images demonstrating microcracks, folds, or flaking, or else reframe the mechanism as a milder change in surface relief rather than surface damage.

7. Implausible XRD phase indexing for medium-carbon 45 steel — Minor

The diffractograms of all states ( Figure 2) show the same peaks (Fe, Cr, C, CrS₂, Cr₂Ti), so UNSM creates no new phases. The change is in peak shape near 2θ ≈ 43

The authors index the X-ray diffractograms of 45 steel in Figure 2a with phases labeled as C (~29°), CrS2/Cr (~43.5°), Fe/Cr (~50.8°), CrS2 (~74.5°), and Cr2Ti (~82°). However, according to Table 1, 45 steel contains <= 0.25 wt.% Cr, no Ti, and only trace sulfur, making the presence of dominant CrS2, Cr2Ti, and free C diffraction peaks physically inconsistent with a medium-carbon steel; moreover, standard body-centered cubic (bcc) alpha-Fe peaks at ~44.7° (110) and ~65.0° (200) are absent, while the peaks at ~43.5°, ~50.8°, and ~74.5° correspond closely to face-centered cubic (fcc) austenite (111), (200), and (220) reflections. The authors need to verify whether the XRD specimens were actually 45 steel or an austenitic/coated steel, provide the ICDD/JCPDS reference cards used for peak indexing, and correct the phase identification.

8. Unreplicated friction testing and unverified substrate state — Critical

Tribological testing was performed once for each experimental condition; therefore, the statistical dispersion of the coefficient of friction was not ca lculated.

The headline conclusion that the 20F mode provides the lowest friction coefficient and optimal hardening relies on a single tribological test per condition (n = 1) and an uncharacterized substrate material. In addition to not verifying the chemical composition of the steel experimentally, the initial heat-treatment state is omitted even though the reported as-received hardness (587 HV) is far above standard annealed or normalized 45 steel (~170–220 HV) and typical of a quenched state, and essential tribological parameters (counterbody ball material, hardness, temperature, and humidity) are not reported. Because a single ball-on-disk run cannot quantify run-to-run variability, the authors should perform replicate friction tests (e.g., n >= 3 independent tracks/specimens per mode), report the counterbody material and environmental conditions, and specify the initial thermal/mechanical history of the 45 steel specimens.

9. Confounded UNSM parameters across treatment modes — Critical

Three UNSM modes (10F, 20F, 30F), each defined by static load, amplitude, feed rate and pass step, were compared with the as - received state by scanning electron microscopy, X - ray diffraction, instrumented and Vickers indentation, profilometry and ball - on - disk

The authors frame the three regimes (10F, 20F, and 30F) as a monotonic increase in treatment intensity to identify an optimal mode and a threshold for over-deformation. However, Table 2 shows that static load (10, 20, 30 N), vibration amplitude (10, 20, 30 μm), and pass step (50, 70, 90 μm) are varied simultaneously across the three modes, while the tip diameter and initial heat-treatment condition of the 45 steel substrate are omitted entirely. Because increasing the pass step from 50 μm to 90 μm reduces the overlap between adjacent passes and lowers the number of impacts per unit area, the design confounds per-impact energy (load and amplitude) with pass overlap density. To support conclusions about treatment intensity and parameter optimization, the authors should either hold the pass step constant while varying impact energy, use a factorial design to separate the effects of load, amplitude, and step size, or explicitly restrict their conclusions to these three specific multi-parameter combinations while reporting all tool geometry and substrate heat-treatment details.

10. Missing untreated baseline cross-section in SEM comparison — Major

Figure 1 shows the cross - sections of the treated samples; the treated surface is at the top of each image. In all three modes a layer with refined grains lies under the surface and passes smoothly into the coarser base metal, without a sharp boundary. The depth of this layer grows with the treatment intensity: in the 10F mode it is thin

The authors claim that all three UNSM modes refine the subsurface grains compared to the base metal, with the 10F mode producing slightly more distinct grain boundaries near the surface. However, Figure 1 only presents cross-sectional SEM micrographs of the treated specimens (10F, 20F, and 30F) and omits a cross-section of the untreated (as-received) specimen at the same magnifications, as well as any description of the metallographic etching procedure used to reveal the boundaries. Including an identically prepared and etched cross-sectional SEM micrograph of the initial state is necessary to establish a baseline for the initial surface microstructure and confirm how much of the near-surface morphology is induced by the 10F treatment.

11. Unspecified sliding distance interval for mean friction coefficient — Major

The friction coefficient (Figure 4c, Figure 5) decreased from 0.712 in the as - received state to 0.668 after 10F and to the minimum of 0.574 after 20F, a 19.4% reduction that combines the harder and the smoother surface.

In Figure 4c, single mean friction coefficients (0.712, 0.668, 0.574, and 0.651) are reported for each condition, while Figure 5 shows that all three UNSM-treated samples undergo a pronounced running-in period over the first 15–20 m where μ starts around 0.20–0.30 and rises steeply toward a steady-state plateau, whereas the Initial sample starts near 0.55 and fluctuates up to ~0.78. The text does not state whether the mean values in Figure 4c were averaged over the entire 0–60 m distance (which mixes transient running-in with steady-state sliding) or over the steady-state regime (e.g., 20–60 m). Looking at Figure 5, between 25 m and 55 m the 10F and 30F curves are virtually indistinguishable (~0.65), and the Initial curve drops back to ~0.65 between 35 m and 55 m. The authors should explicitly define the sliding distance window used to compute the mean friction coefficient and report steady-state friction values separately from the running-in stage.

12. No statistical testing between 20F and 30F modes — Critical

The maximum hardness, the smoothest surface, the lowest friction and the strongest structural change all occur in the same mode, 20F. Weaker treatment (10F) leaves part of the possible hardening unused; stronger treatment (30F) crosses the threshold into over - work hardening.

The central claim that 20F is superior to 30F—and that raising the regime from 20F to 30F degrades hardness and surface roughness—is based entirely on comparing raw arithmetic means without hypothesis testing. In Figure 3a–b (hardness) and Figure 4a–b (roughness), the standard deviation error bars for the 20F and 30F modes substantially overlap (e.g., HIT drops by only 2.2% from 5319 to 5201 N/mm², HV from 694 to 672 HV, and Ra changes from 0.020 to 0.023 μm). Without statistical testing (such as one-way ANOVA followed by post-hoc multiple-comparison tests), it is impossible to rule out that the small differences between 20F and 30F are random measurement scatter. The authors should report the numerical standard deviations, conduct formal statistical comparisons across all modes, and temper the claim of an optimum at 20F if the differences relative to 30F are not statistically significant.

13. Lack of quantitative layer depth and grain size measurements — Major

tests. All modes formed a layer of refined grains under the surface, and its depth grew with the treatment intensity. Raising the intensity from 20F to 30F did not improve the

The claim that the depth of the refined grain layer grows with treatment intensity and that grains are refined in all modes rests solely on visual inspection of the SEM micrographs in Figure 1. No quantitative measurements of the modified layer thickness or grain size distributions are provided, and in Figure 1a–f the visible near-surface zone appears to be of comparable thickness (~10–15 μm) across the micrographs rather than showing a quantified progression. The authors should measure and report the thickness of the plastically deformed layer and the mean grain/cell size (with standard deviations across multiple fields of view) or use cross-sectional microhardness profiles versus depth to quantitatively substantiate the claimed increase in layer depth.

14. Unsubtantiated interpretation of grain morphology in 20F and 30F — Minor

and the grain boundaries near the surface are only slightly more distinct (Figure 1a, d); in the 20F mode a layer of f ine equiaxed grains forms under the surface (Figure 1b, e); in the 30F mode the layer is deepest and the grains below the surface are elongated along the impact direction (Figure 1c, f). The elongated grains show the

The authors state that the 20F mode forms a layer of fine equiaxed grains under the surface whereas the 30F mode produces grains elongated along the impact direction, which they interpret as the first sign of over-deformation. Visually, the cross-sectional SEM micrographs in Figure 1b, e (20F) and Figure 1c, f (30F) both display similar vertical/columnar features extending downward into the bulk and a thin bright near-surface zone (~5–10 μm thick), without a clear morphological transition from fine equiaxed grains in 20F to impact-elongated grains in 30F. Furthermore, severe plastic deformation under sliding/impact normally shears and elongates grains parallel to the surface rather than perpendicular to it. Higher-magnification imaging (or EBSD/TEM characterization) and quantitative aspect-ratio measurements are needed to verify the true grain morphology in the near-surface layer before attributing the 30F structure to over-deformation.

15. Low indentation loads on unpolished rough surfaces — Major

Microhardness was measured by instrumented indentation using a FISCHERSCOPE HM2000 hardness tester (Helmut Fis cher GmbH, Sindelfingen, Germany). The maximum applied load was 50 mN, the loading time was 15 s, and the holding time at the maximum load was 5 s. Additional measurements were performed using the Vickers method with an HVS - 1MDT - AXY semi - automatic microhar dness tester (China) under a load of 0.01 kgf and an indentation dwell time of 10 s.

Surface microhardness was measured using a 50 mN maximum load for instrumented indentation (FISCHERSCOPE HM2000) and a 0.01 kgf (~98 mN, HV0.01) load for Vickers indentation. At such ultra-low loads on steel of ~600–700 HV, the Vickers indent diagonal is only ~5–6 μm and the contact depth is below 1 μm, making the measurements highly sensitive to surface roughness, local work-hardening variations, and indentation size effects if performed directly on the as-treated surface rather than a polished surface. The authors should clarify whether the indentations were made on the top treated surface or on polished cross-sections, and report the indentation depth and diagonal size relative to surface roughness.

XSci (AI review)

October 21, 2026

Summary

The manuscript compares three ultrasonic nanocrystal surface modification (UNSM) settings on 45 steel — 10F, 20F and 30F, differing in static load, vibration amplitude and pass step — against the as-received state, using SEM, X-ray diffraction, instrumented and Vickers indentation, profilometry and ball-on-disk tests. All three are reported to form a refined-grain sublayer whose depth grows with treatment intensity, with no new phases. The 20F mode gives the highest hardness (HIT 3962.15 → 5318.90 N/mm², +34.2%; 587 → 694 HV), the lowest roughness (Ra 0.034 → 0.020 µm) and the lowest friction coefficient (0.712 → 0.574, −19.4%). Raising the intensity to 30F reverses each trend, which the authors attribute to saturation of strain hardening and the onset of surface damage.

Contribution and Significance

The contribution is an applied process-window result: for one medium-carbon steel on one UNSM machine, five independently measured quantities — instrumented hardness, Vickers hardness, Ra, Rz and the friction coefficient — place the optimum at an intermediate setting and all degrade when it is pushed further. The practical value lies in that convergence and in the location of the turning point.

The advance over the closest prior work is modest, and smaller than the framing suggests. That UNSM hardens medium-carbon steel, smooths it and lowers friction is established by Cao, Pyoun and Murakami (ref. [5]) on S45C and by the review in ref. [3]; that an optimum exists and that excessive load roughens and damages the layer is already stated in the authors' own Introduction ("excessive static load or treatment intensity may produce pronounced surface relief", citing [3,4]) and was the subject of ref. [8]. What is new is the numerical window for this steel, not the phenomenon. The authors should also engage with Karimbaev, Choi, Pyun and Amanov, "Mechanical and Tribological Characteristics of Cladded AISI 1045 Carbon Steel", Materials 13 (2020) 859, doi:10.3390/ma13040859, which reports UNSM on AISI 1045 with Ra and Rz reduced by 74.6–85.9% and hardness raised by about 23%, but no significant friction reduction.

Strengths

  • Five independent measures and the XRD line broadening (Sections 3.2–3.5) select the same mode, a stronger internal cross-check than any one of them alone.
  • The non-monotonic result is reported rather than smoothed over: 30F is worse than 20F on hardness (Figure 3), roughness (Figure 4a, b) and friction (Figure 4c), consistent with the elongated grains in Figure 1c, f.
  • Sampling for indentation and roughness is adequate — 15 indents and 10 roughness locations per condition, with standard-deviation error bars (Section 2; Figures 3 and 4).
  • The authors are candid about what they did not do: Section 2 states that the composition was not measured and the tribological test run once, and Conclusion 5 flags that wear life needs confirmation.

Recommendation

Major Revision for Coatings. The process-window result is of the kind this venue publishes, and the trends are consistent across methods. But three of the four central claims rest on weaker evidence than the text asserts: the friction result comes from unreplicated single runs, the structural claim is qualitative and internally inconsistent, and the XRD section reports phases the composition cannot contain while inferring a stress it never measured. All are repairable within the authors' own approach, and I expect the core finding to survive revision.

Major Concerns

  1. The friction claim rests on a single unreplicated test per condition (Sections 2 and 3.5; Figures 4c and 5). The authors state that "Tribological testing was performed once for each experimental condition; therefore, the statistical dispersion of the coefficient of friction was not calculated." Yet friction is one of three headline quantities, and the values 0.712, 0.668, 0.574 and 0.651 are quoted to three decimals and converted into a 19.4% reduction and a non-monotonic rise at 30F. Run-to-run scatter in dry ball-on-disk sliding on steel is routinely of order 0.05, comparable to the 30F-versus-20F difference used to argue over-treatment. At least three repeats per condition are needed, with mean and scatter reported.

    Two gaps compound this. The counterbody material and the test environment are never stated, so the test cannot be reproduced. And no wear quantity is measured — neither wear rate nor wear-track cross-section nor SEM of worn surfaces — although wear resistance is the stated motivation in Section 1.

  2. The modes vary three parameters at once, so no effect can be attributed and "optimal" means only "best of three" (Table 2; Sections 3.6 and 4). Static load (10/20/30 N), amplitude (10/20/30 µm) and pass step (50/70/90 µm) all change together, so load, amplitude and coverage cannot be separated. The pass step also moves in the opposite sense to the other two: a larger step means fewer overlapping impacts per unit area, so the ordering 10F < 20F < 30F in "treatment intensity", on which Conclusion 1 and the over-deformation argument depend, is assumed rather than established. Either hold the pass step fixed while varying load and amplitude, or report a quantitative intensity measure such as impacts per unit area.

    The starting state is likewise undefined. No heat-treatment history is given, and no pre-treatment surface preparation is described although a baseline Ra of 0.034 µm implies careful polishing. The as-received 587 HV corresponds to roughly 55 HRC, far above normalized 45 steel at some 200–220 HV, so the specimens were evidently quenched and tempered. Since UNSM response depends on the initial microstructure — as the authors note — this makes the results hard to place or reproduce.

  3. The grain-refinement claim is qualitative and internally inconsistent (Sections 3.1 and 3.6; Figure 1; Conclusion 1). Conclusion 1 states that "the depth of the layer grows with the treatment intensity", but no depth is measured: Section 3.1 reports only that the 10F layer "is thin" and the 30F layer "is deepest". No grain size is given, and no crystallite size or microstrain is extracted from the broadened peaks; SEM at ×2000, the highest magnification shown, cannot resolve the sub-micron structure implied by "nanocrystal". The two sections also contradict each other: 3.1 places the deepest, most strongly deformed layer at 30F, while 3.6 asserts that "the strongest structural change" occurs at 20F. Measured layer depths with their scatter, Williamson–Hall or Scherrer analysis, and ideally EBSD of the 20F layer would settle both points.

  4. The XRD section reports implausible phases and infers a stress it does not measure (Section 3.2; Figure 2). The phases listed are "Fe, Cr, C, CrS₂, Cr₂Ti", but Table 1 gives Cr ≤ 0.25 wt.% and no Ti or S. Elemental chromium, elemental carbon, a chromium disulfide and a Cr₂Ti Laves phase cannot be present at detectable concentrations; the expected constituents are α-Fe and Fe₃C, with martensite and possibly retained austenite given the baseline hardness. This reads as an unfiltered automatic search-match and should be re-indexed against a phase list consistent with Table 1, since Conclusion 1 depends on it. Separately, the claim that a shift to higher angles "indicates ... residual compressive stress" does not follow in the θ–2θ geometry of Section 2: at ψ = 0 the measured d-spacing is normal to the surface, and in-plane compressive stress expands it by the Poisson effect, shifting the peak to lower 2θ. Either perform a sin²ψ analysis or attribute the broadening to refinement and microstrain only.

Minor Comments

  1. Reference [6] (Aringozhina et al.) studies Ti-6Al-4V but is cited in Section 1 for "Studies on AISI 1045 steel", and reference [5] (Cao et al., S45C) is cited for "Studies on AISI 1050 medium-carbon steel".
  2. References [7] and [9] appear in the reference list but are never cited in the text.
  3. The 20F increase is +34.2% by instrumented hardness but +18.2% by Vickers (587 → 694), a gap an absolute-scale offset cannot explain, so "the two methods agree" (Section 3.3) needs justification.
  4. The abstract and Conclusion 4 state that hardness "fell by 2.2%" from 20F to 30F, which is the instrumented value; by Vickers the drop is 3.2% (694 → 672), so name the measure.
  5. Rz is given only for 20F (0.341 µm) and 30F (0.386 µm) in Section 3.4, so the stated Rz trend cannot be checked against the as-received and 10F states.
  6. The number of UNSM passes, the tip material and diameter, whether lubricant was used during treatment, and the polishing and etching route for the cross-sections are all unreported.
  7. A table of mean ± standard deviation for HIT, HV, Ra and Rz, with the profilometer sampling length and cut-off, would show whether the roughness differences (0.034 → 0.027 → 0.020 → 0.023 µm) exceed the scatter; values this low are unusual for a 50–90 µm pass step.
  8. Section 3.3 states the "saturation of strain hardening" mechanism as established while the abstract and Conclusion 4 hedge it; the hedged wording is the defensible one.
  9. A microhardness depth profile across the cross-section, standard in this literature and obtainable with the instrument already used, would strengthen the argument.
  10. The term "nanocrystal" is carried from the method name into claims about the resulting structure without evidence of nanoscale grains; otherwise call the layer ultrafine-grained.