XSci

Understanding through Perturbation: lowering classifier-free guidance as a dose-response assay for two text-to-image latent models

Youssef Hassan

Submitted by Youssef Hassan

Published October 22, 2026 · Version v1, October 22, 2026 · DOI 10.66977/xsci.2610.002a

Artificial Intelligence, Machine Learning, Computer Vision

Abstract

I probe a generative model by lowering one control, pre-registered, and scoring what breaks with a rubric borrowed from Klüver. I generated 860 images on two latent text-to-image checkpoints, SDXL and SD 3.5: 6 prompts, 7 guidance values, 10 seeds, scored blind by two vision-language judges on criteria I committed to git before the run; two humans rated a subset. Lower classifier-free guidance was associated with greater rubric-scored visual breakdown, and the association remained after adjustment for two no-reference quality proxies, robustly to prompt resampling on SDXL but not on SD 3.5. SDXL met every pre-registered gate under the post-data amended judge panel. SD 3.5 missed the slope gate: its slope of -0.182 sits above the -0.20 line, and its interval straddles that line, so an effect of the registered size is neither shown nor ruled out. Looking afterwards, almost all of SD 3.5's drop happens between g = 1 and g = 2. A second pre-registered rubric, adapted from Suzuki's axes, replicated on SDXL and failed on SD 3.5, where veridicality moved opposite to the registered direction. Qwen2.5-VL-7B, the original second judge, failed silently, returning well-formed zeros on visibly broken images, and was caught only by a human subset after the run; Qwen3-VL-8B failed the same way in screening. Replacing the 7B with Qwen3-VL-32B, a post-data amendment, raised composite kappa from 0.290 to 0.562 (SDXL) and 0.158 to 0.440 (SD 3.5; 0.394 without the empty-prompt baselines); the two humans agreed at 0.567, and with the best judge at 0.337 and 0.426. An earlier experiment found no Klüver form constants, but its judge also flagged them on 45% of ordinary images, above a registered ceiling of 20%, so that null is uninterpretable under its own rule. The psychedelic analogy supplies the rubric and is not tested; code, pre-registrations, images and every judge reply are public. Code, pre-registrations, analyses and every judge reply: https://github.com/youssefhassan/operating-system-hypothesis-public (tag preprint-I-v1). Images and judgements: Hugging Face datasets youssefhassan13/exp01-guidance-sweep, youssefhassan13/exp02-form-constant-generator, youssefhassan13/exp03-l23-hardening.

View PDF

Review reports

Reviewer3 (AI review)

October 22, 2026

AI Review (reviewer3.com)

Comments (7)

1. Composite averages judges before z-scoring despite unequal variance — Critical

Per image and field, the judge-mean 0-3 score, z-scored across all conditioned images within a model ; the composite is the per-image mean of the four z-scored fields. The endpoint is therefore judge-

The primary endpoint is formed by averaging the two judges' raw 0-to-3 scores per field before z-scoring across conditioned images. However, Figure 6 demonstrates that Qwen3-VL-32B has substantially compressed variance and lower mean usage than Claude Sonnet 5 across all four fields (e.g., on fragmentation Qwen3-VL-32B scores above zero on only 4% of probe images with a mean of 0.07, whereas Claude scores above zero on 14% with a mean of 0.14; on condensation 11% vs. 43%). Averaging raw scores before standardizing means that the sum is dominated by the higher-variance judge (Claude Sonnet 5), and given that Qwen3-VL-32B showed near-zero agreement with human raters (kappa = 0.124 and 0.169), the composite is effectively a noisy version of Judge A rather than a balanced two-judge composite. The author should report a sensitivity analysis where each judge's scores are z-scored within judge and field prior to averaging across judges, or clarify in the text that the raw-averaged composite heavily weights Claude Sonnet 5.

2. Combined interaction model ignores correlated residuals across checkpoints — Major

Comparing -0.340 and -0.182 by eye ignores the uncertainty in each, so the difference was tested directly: one mixed model fitted on both checkpoints together, with a term that lets the guidance slope differ between them (a model by guidance interaction, pre-specified on 2026-09- 17 and exploratory).

To test whether SDXL's dose-response slope is steeper than SD 3.5's, the author fits a combined linear mixed model across both checkpoints with a model-by-guidance interaction. However, the exact specification of the random effects in this combined model is not given. Because both checkpoints were evaluated on the identical 6 prompts and seeds 42-51, prompt and seed intercepts (and potentially prompt-by-model random intercepts) are crossed across checkpoints. If the combined model only includes (1 | prompt) + (1 | seed) without allowing baseline breakdown per prompt to vary by checkpoint ((1 | prompt:model)), differences in prompt-specific baselines between SDXL and SD 3.5 are pooled into the residual variance, which can distort the standard error and confidence interval of the interaction term. The author should state the exact formula for the combined interaction LMM and verify that checkpoint-specific prompt random effects are accounted for.

3. Averaging negatively correlated quality proxies obscures opposing signals — Minor

to which prompts were run. The two quality components, CLIP-IQA and the aesthetic predictor, agree poorly with each other, Spearman -0.155 on SDXL and +0.170 on SD 3.5; adjusting for either component separately still leaves a negative partial correlation.

The quality adjustment operationalizes general image quality Q by z-scoring CLIP-IQA and a LAION aesthetic predictor and averaging them into a single composite score. As the author notes in the Limitations, these two components are negatively correlated on SDXL (Spearman -0.155) and only weakly positively correlated on SD 3.5 (+0.170). When two standardized variables are negatively correlated, their simple average cancels out opposing variance rather than extracting a shared quality factor, which can artificially attenuate the ability of Q to explain variance in the partial correlation test. While the author notes in Section 5 that adjusting for either component separately still leaves a negative partial correlation, the exact partial rho values and confidence intervals for the separate adjustments and for a bivariate partial correlation controlling for both proxies simultaneously (without averaging them) are not reported in the tables. The author should report the specific partial correlation estimates when controlling for CLIP-IQA and LAION aesthetic score as two separate covariates Simultaneously.

4. Prompt-Generality Gate Includes the Negative Control Prompt — Critical

requiring every gate on both architectures, is not confirmed. The forest prompt, the pre-registered low-objecthood control, is counted inside both of those tallies; it is read as a control below rather than as a sixth ordinary prompt.

The third confirmation gate requires at least 5 of 6 prompts to show a negative per-prompt Spearman slope. However, the sixth prompt (p6_forest) was explicitly pre-registered as a low-objecthood negative control predicted to stay flat on object-bound breakdown. Including a negative control in the tally of prompts required to show the effect conflates experimental and control arms: on SDXL, the failure of the control to remain flat (rho = -0.62) is counted toward passing the 6/6 generality gate, whereas on SD 3.5, if the control had behaved as predicted by staying flat or positive while one ordinary prompt (p2_portrait, +0.30) also failed, the checkpoint would have failed the 5/6 gate specifically because its negative control worked. The author should report the prompt-generality gate restricted to the five test prompts (requiring 4/5 or 5/5) alongside the 6-prompt tally.

5. Empty-prompt baselines receive arbitrary intended-scene rubrics — Critical

Each judge receives the image and one of the two prompts below, verbatim. The first sentence of each names the intended scene; it is shown here for the still-life prompt (“a watermelon, a glass half-filled with water, and a set of keys on a wooden table”).

The design includes 10 empty-prompt baseline images per checkpoint that are scored by the VLM judges and included in the full-set inter-judge kappa gate (which is needed for SD 3.5 to clear the 0.40 threshold, rising from 0.394 on conditioned images to 0.440 with baselines). However, the Klüver rubric prompt shown in Section 9 requires naming an explicit intended scene (e.g., "This image was meant to depict: ..."), and the paper never specifies what intended scene description was passed to the judges when evaluating empty-prompt images. Because reduplication is explicitly defined relative to intended content ("repetition BEYOND that intended content"), scoring an unconditioned image against either an arbitrary prompt or an empty string changes the task definition for those 10 images and artificially inflates inter-judge agreement at the extreme of the scale. The author should document the exact rubric text passed to the judges for the empty-prompt baseline images and justify why images evaluated against a different or vacuous prompt specification belong in the reliability gate for conditioned dose-response.

6. Partial Spearman correlation ignores prompt and seed clustering — Minor

The guidance association is then re-estimated as a partial correlation adjusting for Q. The pre-registration named a quality-

While the primary slope gate uses a linear mixed model to account for non-independence across the 70 images sharing each prompt and 42 images sharing each seed, the second confirmation gate (quality adjustment) relies on a pooled partial Spearman correlation across all ~418 conditioned images without accounting for prompt or seed clustering. As the author notes when motivating the mixed model in Section 2.7, "a busy forest scene scores more breakdown than a portrait at every guidance value. A plain regression would let those prompt differences leak into the guidance effect." The same leakage applies to the pooled partial Spearman correlation if prompt baselines differ in both quality Q and breakdown composite. Although a prompt-cluster bootstrap is reported for the confidence interval, resampling clusters does not remove between-prompt confounding from the point estimate itself. The author should report the fixed-effect guidance slope from the linear mixed model with Q (or both quality proxies) included as covariates (composite ~ guidance_std + Q + (1 | prompt) + (1 | seed)) to ensure the quality-adjusted estimate is within-prompt.

7. Screening probe used to select Qwen3-VL-32B on the same corpus — Major

Every candidate judge scored the same stratified subset of 28 images, on the rubric it would use, under the blinding and decoding of the run. On the Klüver rubric that screen was run on 2026-08- 08, after the full pass of 2026-07-22 and not before it; on the axes rubric it ran before the pass, as

In Section 3.4, the 28-image screening probe used to disqualify silent-failing judges and select Qwen3-VL-32B was drawn as a stratified subset from the Exp 03 corpus itself, and those 28 images remained in the full corpus (n = 428 and n = 427) for the primary and reliability analyses. Although selection was based only on non-zero variance (gradedness) rather than directional agreement with the hypothesis, screening candidate models on a subset of the analysed dataset and then evaluating full-corpus reliability including that subset introduces a mild selection dependency. The author should verify and state whether the primary mixed-model slopes and inter-judge kappa gates remain unchanged when the 28 screening images are excluded from the full-corpus evaluation.

Author response

All seven comments are correct on the facts. I reran the analyses they ask for on 2026-10-22, with each check written down before running; the script and its output are in the public repository. None of them changes a verdict.

1. Composite averages judges before z-scoring. Correct. Recomputed with each judge's scores z-scored within judge and field before averaging. The SDXL slope moves from -0.340 [-0.400, -0.279] to -0.308 [-0.361, -0.254]; SD 3.5 from -0.182 [-0.248, -0.115] to -0.158 [-0.213, -0.102]. Both sit between the two single-judge slopes already reported (Claude alone -0.321 and -0.174, Qwen alone -0.295 and -0.141). The registered composite does lean toward Claude, by about 0.03 of slope. The verdicts are unchanged. The next version will state the weighting in the text and carry the within-judge composite in the sensitivity table.

2. Interaction model random effects. The published fit used (1|prompt) + (1|seed) shared across checkpoints, which the paper should have stated. Refitted with (1|prompt:model) + (1|seed:model) added: the SDXL minus SD 3.5 interaction is -0.158 [-0.248, -0.067] in the published specification and -0.158 [-0.248, -0.068] with checkpoint-specific intercepts. The formula will be given in full.

3. Quality proxies controlled separately and together. Partial Spearman of composite against guidance, controlling CLIP-IQA and the aesthetic score as two separate covariates: SDXL -0.501 [-0.569, -0.425] (image bootstrap; prompt-cluster bootstrap [-0.592, -0.364]), SD 3.5 -0.234 [-0.329, -0.132] (prompt-cluster [-0.429, +0.054]). Controlling each alone: CLIP-IQA -0.509 and -0.242, aesthetic -0.465 and -0.213; the registered averaged Q gives -0.433 and -0.246. The averaged proxy is the most conservative of the four on SDXL. These will go in the table.

4. Forest control inside the 5-of-6 gate. The gate as pre-registered counts six prompts, and the same registration marks the forest prompt as the control, so the tally in the paper is the registered one. The reviewer's point stands: restricted to the five test prompts, SDXL is 5/5 and SD 3.5 is 4/5, and on SD 3.5 the sixth negative sign is the control at -0.02, which is flat, not a sixth confirmation. Both tallies will be reported.

5. Empty-prompt rubric. The judges received a distinct variant for the baselines, which the paper omitted. The intended-scene sentence is replaced by: "This image was generated from an EMPTY prompt (the model's own prior, with no intended scene). There is no 'correct' content. Score only the phenomena listed below on whatever is visibly present." It is in rubric.py in the repository and will be added to the verbatim-prompt appendix. The reliability consequence is already in the paper: SD 3.5's kappa is 0.440 with the ten baselines and 0.394 on conditioned images alone, and I report both because the registered set includes the baselines and the conditioned-only number is the stricter reading.

6. Quality adjustment inside the mixed model. Guidance fixed effect with Q as a covariate, same random intercepts: SDXL -0.270 [-0.339, -0.201], SD 3.5 -0.157 [-0.225, -0.090]. With the two proxies as separate covariates: SDXL -0.237 [-0.313, -0.161], SD 3.5 -0.164 [-0.233, -0.094]. On SDXL the within-prompt adjustment removes about a third of the slope, more than the pooled partial correlation suggested, and what remains clears the registered -0.2 bar with the interval away from zero. That is the honest number for the quality question and it will replace the pooled partial as the headline adjustment, with the pooled value kept because it is what was registered.

7. Screening images inside the corpus. The 28 screening images are the human-rated subset (13 SDXL, 15 SD 3.5 among complete cases). Dropping them: SDXL slope -0.349 [-0.411, -0.287], partial rho -0.441, composite kappa 0.569 [0.521, 0.610] (conditioned only 0.549), tally 6/6 and 5/5; SD 3.5 slope -0.180 [-0.247, -0.113], partial rho -0.247, kappa 0.440 [0.376, 0.497] (conditioned only 0.392), tally 5/6 and 4/5. No change to the second decimal except the SDXL kappa, which rises.

Youssef Hassan

xPeerd (AI review)

October 22, 2026

AI Review (xPeerd — DAReview)

Summary

This manuscript presents an ambitious and unusually transparent perturbation study of text-to-image generation. Its central claim is that lowering classifier-free guidance is associated with greater judge-scored “visual breakdown” on a Klüver-derived rubric, with stronger and more reproducible evidence for SDXL than for SD 3.5. The work’s strengths are its pre-registration logic, public release of code/data/judge outputs, explicit reporting of failed controls and failed judge behavior, and repeated efforts to distinguish the main effect from generic image-quality decline. The abstract accurately states a key asymmetry: “SDXL met every pre-registered gate… SD 3.5 missed the slope gate” . The paper is also commendably careful in discussion about what is not being claimed, especially regarding the psychedelic analogy and biological transfer .

My main concern is that the evidential core still depends on a post-data amendment to the judge panel, limited human validation, and a construct that is not yet cleanly separated from prompt adherence, painterliness, or generic degradation. The manuscript itself concedes that “the panel change is therefore a post-data amendment” and that prompt adherence remains “an unmeasured competing explanation” . I do not see obvious signs of paper-mill fraud or fabricated scholarly structure; on the contrary, the author openly reports failures and deviations. However, the present version remains methodologically vulnerable in ways that materially limit the strength of its conclusions.

Potential Major Revisions

  1. The main result relies on a post-data instrument amendment, which weakens confirmatory force.

The manuscript is unusually candid about this issue, but the problem remains substantial. Section 2.5 states that “The panel reported throughout is two model judges… It is not the panel that ran first” and that the judge B seat “was then refilled with Qwen3-VL-32B” after post-run screening exposed inert raters . Section 3.4/Limitations goes further: “In Exp 03 the screen came after the run, and the panel change is therefore a post-data amendment. The rule is what this experiment produced, not what it followed” . The abstract likewise foregrounds that the replacement judge was “a post-data amendment” .

This is not a minor procedural deviation. Because the principal endpoint is judge-scored, changing the judge panel after observing failure changes the measuring instrument itself. The author argues persuasively that the amendment improved reliability, e.g., “raised composite kappa from 0.290 to 0.562 (SDXL) and 0.158 to 0.440 (SD 3.5)” , but that improvement does not restore confirmatory status. The current manuscript sometimes reads as though the amended result is still close to pre-registered confirmation. I think the framing should be tightened: the paper demonstrates a promising amended assay, but not a fully confirmatory primary test in the strong sense implied by the pre-registration narrative.

Revision needed: recast the core conclusion more explicitly as amended-confirmatory or quasi-confirmatory, not straightforwardly confirmatory. Separate pre-amendment and post-amendment evidential status in the title, abstract, and conclusions.

  1. Human validity of the endpoint remains too weak for strong claims about “breakdown.”

The manuscript states in Section 2.7 that the “endpoint is therefore judge-scored breakdown on the Klüver-derived rubric, not human-perceived breakdown” . This is the correct caution, but elsewhere the prose still encourages an interpretation closer to genuine visual/object-level breakdown than current validation warrants. The limitation section is blunt: “Human against Qwen3-VL-32B composite kappa is 0.124 with an interval spanning zero, so the second judge has no demonstrated human validity at all” and “two raters on 28 images… are not a validated measure of human-perceived breakdown” . Figure 5’s example also illustrates serious interpretive instability: “Read as objects melting, it is high distortion and condensation; read as a painting style, it is close to none” .

This is a central construct-validity issue. If one judge interprets low-guidance painterliness as object distortion and another interprets it as style, then the endpoint may partly reflect stylistic looseness, realism loss, or prompt adherence drift rather than the specific “breakdown” construct the paper emphasizes. The manuscript already acknowledges this through the exploratory veridicality analysis and the future-work call for a larger human panel , but the present claims should be more conservative.

Revision needed: narrow the claimed construct to “judge-scored rubric movement consistent with breakdown-like phenomena” unless stronger human validation is added. If possible, include a substantially expanded human-rating study before publication.

  1. Competing explanations are not sufficiently ruled out, especially prompt adherence and generic degradation.

The manuscript openly recognizes this concern. Section 3 notes: “Image-text similarity was not measured… that leaves prompt adherence as an unmeasured competing explanation of the composite” . Section 4.1 similarly states: “No alternative degradation… was scored on the same rubric, so I cannot claim that the profile reported above is specific to guidance rather than a generic signature of image degradation” . Section 4.3 lists this as Future Work item 1 and item 4: specificity of perturbation and prompt adherence as a covariate .

These admissions are methodologically appropriate, but they also imply that the main interpretation is underdetermined. The partial-quality adjustment is helpful yet explicitly limited: “The proxies are not a matched quality design… and they cannot rule out kinds of degradation they do not measure” . The trimmed-arm analysis also failed to equalize quality, leaving “standardised mean difference in quality… 0.740 on SDXL and 0.284 on SD 3.5” after trimming .

Revision needed: moderate the interpretive language throughout. The current evidence supports a robust association between lower guidance and rubric score changes, especially on SDXL, but not yet specificity to the proposed breakdown construct. The discussion should elevate this from “future work” to a present central limitation.

  1. The model specification is partly mismatched to the observed response shape.

The paper itself says, “The pre-registered linear endpoint on a near-geometric grid could not distinguish a gradient from a change concentrated at g = 1. That contrast is post-hoc” . Later: “A monotone trend test or an explicit segmented fit was the right registration and is what I would register now” . This is an important self-diagnosed weakness. SD 3.5 in particular appears driven by the lowest guidance condition: “the effect is carried by the g = 1 condition” .

This means the primary inferential model may not be well aligned to the phenomenon it measures. For SD 3.5, the linear slope can understate or mischaracterize a threshold-like effect. Since the paper’s comparative narrative between SDXL and SD 3.5 partly rests on profile shape, reliance on a linear pre-registered endpoint complicates interpretation.

Revision needed: give non-linear or segmented analyses greater prominence in the main text, not only as post-hoc addenda, while clearly marking them exploratory. Also temper any theory-level claims that depend on shape differences between checkpoints.

  1. Architecture-level interpretation is overconstrained by sample size at the model-family level.

The study compares one SDXL checkpoint and one SD 3.5 checkpoint, but the manuscript acknowledges that “architecture here is confounded with training data, training objective, text encoder and sampler” . Future Work item 3 correctly notes: “Without it the difference between the two checkpoints cannot be attributed to the architecture” .

This is important because the manuscript sometimes frames the contrast as SDXL versus SD 3.5 in a way that can invite broader architectural inference. At present, the evidence only supports checkpoint-specific comparison, not architecture-general distinction.

Revision needed: revise wording throughout to avoid implying architecture-level generality beyond the two tested checkpoints.

  1. The control structure does not fully stabilize the object-bound interpretation.

A notable adverse result appears in Section 3: “The forest control’s composite tracked guidance on SDXL, so the object-bound reading of the breakdown is not established” . The more detailed result is also explicit: “On SDXL the forest composite still tracks guidance, rho -0.62, so the control did not stay flat and the object-bound reading of the breakdown is not established by it” .

This is a serious challenge because the manuscript’s conceptual pitch depends on the rubric naming phenomena rather than generic quality. If the designed control does not remain flat at the composite level, then the interpretation of object-level disruption remains provisional.

Revision needed: integrate this failed control more centrally into the abstract/discussion balance. At present it is not fully reflected in the headline framing of the assay’s success.

  1. The Exp 01 / Exp 02 instrument history complicates the broader narrative of the program.

The paper responsibly reports that the earlier form-constant result became uninterpretable because specificity failed: “its class flags fire on 45% of ordinary generated images, above the ceiling of 20% fixed in advance” ; see also Table 8 and surrounding text . This honesty is a strength. However, it also means the broader programmatic narrative contains multiple cases where the operative instrument changed or failed after the fact. That is not misconduct, but it does reduce the maturity of the assay relative to the confidence level sometimes conveyed by the paper’s contribution framing.

Revision needed: make clearer that the manuscript is best read as a careful assay-development paper with a substantive empirical signal, rather than a settled demonstration of a validated construct.

Potential Minor Revisions

  1. Typographic, grammatical, and phrasing issues

I did not find pervasive copyediting problems in the extracted text; the prose is generally strong, controlled, and internally consistent. However, several phrasing choices could be improved for precision or readability.

Page Section Quoted text Issue Suggested revision
1 Abstract “scored blind by two vision-language judges on criteria I committed to git before the run” “committed to git” is technically understandable but stylistically informal for the abstract of a research paper Consider “pre-registered in a version-controlled repository before the run”
1 Introduction “The adaptation is not cosmetic” Rhetorically forceful, slightly informal Consider a more neutral phrasing such as “The adaptation is substantive rather than terminological”
2 Contributions “silent judge failure, and the screen that catches it” Slightly journalistic heading tone relative to surrounding formal register Consider “silent judge failure and a screening procedure to detect it”
8 Endpoints/statistics “If that were the whole story, the paper would have measured nothing but ‘low guidance makes worse pictures’, which everyone already knew” Conversational phrasing (“everyone already knew”) is too informal for some venues Replace with a neutral scholarly wording such as “which would reduce the contribution to a known quality-related effect”
20 Discussion 4.1 “I perturbed one knob” Stylistically vivid but informal Consider “I manipulated a single control parameter”
21 Discussion 4.2 “The assay is a package another group can pick up and run” Informal idiom Consider “The assay is intended to be readily reusable by independent groups”
22 Limitations “‘Blind to guidance’ is weaker than it sounds” Strong and clear, but slightly conversational Consider “the blinding was only partial with respect to visually inferable guidance condition”
  1. Formatting and presentation issues
Page Section Issue Comment
8 Table 3 The table is informative but should be visually tied more clearly to the corresponding prose on the four gates Consider adding a sentence immediately after the table explicitly stating which later analyses map to each gate
6 Table 2 The judge panel table is important but dense Consider separating “reported panel,” “original pre-registered panel,” and “screened candidates” into clearer rows or subsections
20 Table 8 / Exp 02 discussion The instrument-failure result is highly consequential and deserves stronger visual emphasis Consider moving the interpretive sentence “the Exp 01 null is reclassified as uninterpretable” into a boxed takeaway or subsection summary
11–16 Results Results mix confirmatory and exploratory analyses closely A stronger typographic distinction between pre-registered primary analyses and exploratory follow-ups would improve readability and epistemic clarity
23 Reproducibility The repository/command block is valuable For journal style, consider moving exact shell commands to supplement and retaining a concise reproducibility statement in the main text
  1. Consistency and terminology refinements
Page Section Issue Comment
1–2 Introduction / contributions “breakdown,” “visual breakdown,” “object-level breakdown,” and “judge-scored breakdown” are all used These should be more tightly standardized, since they imply different construct strengths
8, 21–22 Statistics / limitations The manuscript carefully distinguishes adjustment, sensitivity analysis, and causal claims This distinction is good; it should be maintained uniformly in abstract and conclusion as well
14, 20–22 Exp 03b / discussion / limitations The veridicality analysis is labeled exploratory in some places but carries substantial interpretive weight Ensure every major reference to this contrast keeps the exploratory label visible
  1. AI content analysis for this post-2021 manuscript

Estimated percentage of AI-generated content: low to moderate, approximately 10–25%.

Basis for estimate: The manuscript shows several hallmarks of strongly human-authored, methodologically self-aware writing: admission of failure, nuanced qualification of claims, idiosyncratic argumentative structure, and sustained consistency in discussing pre-registration deviations. For example, statements such as “The rule is what this experiment produced rather than what it followed” and “I report a reliable effect that misses the registered bar, not an absence of one” are unusually self-critical and context-sensitive. That said, some passages are highly polished, repetitive in cadence, and abstract-summarizing in a way that could reflect limited AI-assisted drafting or editing, especially in contribution lists and explanatory prose.

Highlighted AI-suspect sections:

  • Abstract and contribution-list passages with highly compressed, balanced phrasing, such as “The psychedelic analogy supplies the rubric and is not tested; code, pre-registrations, images and every judge reply are public” .
  • Some explanatory sections on statistical gates and limitations that use rhetorically clean, parallel sentence structure .

Assessed epistemic impact: If AI assistance was used, I do not see strong evidence that it materially undermines the manuscript’s scholarly contribution. The main risks here are stylistic smoothing, occasional overcompression, and possibly overstated coherence in narrative framing, not fabricated citations or nonsensical methodology. The substantive vulnerabilities of the paper are methodological and construct-validity related, and they are already largely visible from the author’s own disclosures. I do not detect classic paper-mill traits such as incoherent citation patterns, meaningless jargon inflation, impossible claims, or disciplinary mismatch. On the contrary, the manuscript’s explicit reporting of negative controls, failed specificity, post-hoc amendments, and non-convergence issues argues against fraudulent packaging.

Recommendations

  1. Reframe the manuscript explicitly as a strong assay-development study with a substantive empirical signal, rather than as a near-settled validation of a breakdown construct. This would better match the evidence and would likely strengthen credibility.

  2. Tighten the abstract and conclusion so that the post-data judge replacement is not merely disclosed but incorporated into the evidential interpretation. The main result should be described as dependent on an amended panel.

  3. Expand human validation substantially if feasible. A larger blinded human panel using the exact rubric would materially improve the paper. At present, the manuscript itself shows that one machine judge lacks demonstrated human validity and that the second human sample is too small .

  4. Add direct measurement of prompt adherence or image-text alignment in the next revision if possible, or at minimum make this competing explanation more central in the present discussion, since the paper states it remains unmeasured .

  5. Promote the failed or adverse control findings into the main framing. In particular, the forest-control result and the specificity failure of the earlier form-constant judge should be more visibly integrated into the manuscript’s high-level takeaway .

  6. Standardize construct language. Use one primary expression such as “judge-scored rubric breakdown” and reserve broader terms like “object-level breakdown” for carefully qualified discussion only.

  7. For SD 3.5, reduce inferential emphasis on the linear slope and emphasize the uncertainty around a threshold-like response concentrated at g = 1. The manuscript already diagnoses this issue correctly; the presentation should reflect it more consistently .

  8. Keep the strong transparency features. Public code, raw judge outputs, explicit deviations, and open failure reporting are major strengths and should remain central to the paper’s identity .

Overall, I see this as a serious, intellectually honest manuscript with real novelty in assay design and evaluation transparency, but one whose current conclusions should be narrowed because instrument amendment, limited human validation, and unresolved competing explanations still constrain reproducibility and construct validity.

Author response

This is a careful read, and I accept its central recommendation: the paper should be read, and will be written, as an assay-development study with a substantive signal under an amended instrument. Point by point:

Amended panel and confirmatory status (1, 7). I agree with the recommendation and will adopt the wording: the SDXL result is confirmatory under an amended instrument, and the paper is an assay-development study with a substantive signal, not a settled validation of a construct. The abstract and conclusion will say so directly rather than disclosing the amendment and letting the reader weigh it.

Human validity and construct language (2, 6). Agreed. The construct the data support is judge-scored rubric movement; "object-level breakdown" will be confined to the discussion of what a larger human panel would test. The five phrasings in the introduction will be collapsed to one. A larger blinded human panel on the exact rubric is the first item in the next study and is not something I can add to this version.

Competing explanations (3). Prompt adherence was not measured and the report is right that this belongs in the central limitations, not in future work. The strongest quality adjustment the current data allow is the mixed model with the quality proxies as covariates (reported in my reply to the Reviewer3 report): it brings the SDXL slope from -0.340 to between -0.270 and -0.237, still past the -0.2 bar, and it leaves prompt adherence open. Image-text similarity will be scored on the existing images for v2, since the images and prompts are public and no new generation is needed.

Linear endpoint versus a g = 1 step (4, recommendation 7). Agreed. The log2 fit and the segmented reading are in the paper as post-hoc; v2 will move them into the main results with the exploratory label kept, and the SD 3.5 text will lead with the concentration at g = 1 rather than the slope.

Architecture wording (5). Agreed; "checkpoint" throughout, with the architecture confound stated where the two are compared.

Forest control (6). Agreed. With the control removed from the prompt-generality tally, SDXL is 5/5 and SD 3.5 is 4/5, and both tallies will be reported. The failed control will appear in the abstract alongside the gates that passed.

The minor style suggestions I will take selectively: the informal phrasings are deliberate, but the terminology standardisation and the typographic separation of registered from exploratory analyses are improvements and will be made.

Youssef Hassan

XSci (AI review)

October 22, 2026

Summary

The authors treat classifier-free guidance as a dose variable: they generate a fixed grid of 860 images on SDXL and SD 3.5 (6 prompts x 7 guidance values x 10 seeds, plus empty-prompt baselines) and score every image blind with two vision-language judges on a four-field rubric adapted from Klüver's form constants, against gates committed to git before the run. Lower guidance is associated with higher rubric-scored breakdown on both checkpoints and survives adjustment for two no-reference quality proxies, but the registered joint claim fails: SD 3.5's slope of -0.182 [-0.248, -0.115] misses the -0.20 gate, and a second registered rubric adapted from Suzuki's axes replicates on SDXL while failing on SD 3.5 in the opposite direction. Two judges, Qwen2.5-VL-7B and Qwen3-VL-8B, return well-formed JSON with fluent captions and zeros on every field of every probe image; refilling that seat with Qwen3-VL-32B raised composite kappa from 0.290 to 0.562 on SDXL and 0.158 to 0.440 on SD 3.5. A separate form-constant arm is reported as uninterpretable, its judge's class flags having fired on 45% of ordinary images against a registered 20% ceiling.

Contribution and Significance

The durable contribution is instrumental rather than phenomenal. Section 3.4 documents a failure mode every standard pipeline check would miss: judges producing no refusals, no decoding errors and no schema violations, a fluent note on each image, and a constant zero on every graded field. Table 7 prices the consequence: the original three-judge panel reads 0.126 and 0.135, a flat rater dragging weighted kappa toward zero by arithmetic. The accompanying gradedness screen is cheap and reusable, as is the released corpus of 835 conditioned and 20 baseline scored images with raw judge replies and a blind human subset.

The dose-response itself is near-known territory: Kynkäänniemi et al. [5] already describe low guidance as yielding diverse but fuzzy images that lack detail, Saharia et al. [8] characterise the high-guidance end, and Xie et al. [11] show preference evaluators favour high guidance. Section 1.1 claims that "what is new is the rubric that names failure phenomena rather than rating preference or quality", but that is the one component with an existing literature the paper does not engage (Major Concern 3). What is genuinely new is the pre-registration apparatus and the judge audit; pre-registration is process, not finding, so the paper should be positioned on the instrument rather than on the dose-response.

Strengths

  • Figure 6 turns the silent-judge failure into a usable screen with concrete numbers: Qwen2.5-VL-7B and Qwen3-VL-8B flat on all four fields, Llama-3.2-11B-Vision on three of four, Gemma-3-27B on two of four.
  • The bookkeeping is unusually honest: the joint claim reported as not confirmed, the judge swap labelled a post-data amendment, SD 3.5's kappa given both with the baselines (0.440) and without (0.394, below the gate); every figure I recomputed from Tables 4, 5, 7 and 9 is consistent.
  • The checkpoint difference is tested rather than eyeballed, with a model-by-guidance interaction of -0.158 [-0.248, -0.067] that holds on raw scores too (Section 3.2), and architecture attribution explicitly disclaimed.
  • Figure 5 makes the construct problem concrete on one image: author 1, 2, 3, 3; Qwen3-VL-32B 0, 0, 0, 1; Claude Sonnet 5 2, 1, 1, 2, the disagreement traced to reading looseness as melting or as style.

Recommendation

Major Revision for TMLR. The judge audit and the public corpus are contributions TMLR's audience would use, and the reporting standard is high. But the primary endpoint is not yet separated from prompt adherence, the quantity guidance directly controls, and the instrument gate licensing every judge-scored claim is cleared by a post-data panel in which only one member has demonstrated human validity. Both gaps are addressable within the manuscript's own approach, on images already generated and public.

Major Concerns

  1. The composite is not separated from prompt adherence (Appendix 9; Section 5, "Image-text similarity was not measured"). The judge prompt names the intended scene and defines the fields against it: "This image was meant to depict: ... Reduplication means repetition BEYOND that intended content." The manipulated variable is the strength of prompt conditioning, so a score anchored to the prompt and falling as that conditioning rises is at risk of being prompt adherence under another name - the one effect of guidance not in dispute. The authors set CLIP similarity aside deliberately, "because it measures obedience rather than image quality", but that is precisely the reason to include it as a covariate rather than as a quality proxy. This bears on the first central claim and on gate 2: the two no-reference proxies cannot adjust for adherence because they never see the prompt. An image-text similarity score computed on the already-public images, entered alongside Q in the partial correlation and the mixed model, would settle it.

  2. The instrument gate rests on a post-data panel whose second member has no demonstrated human validity (Section 3.4, Table 7, Section 5). Qwen3-VL-32B agrees with the author at composite kappa 0.124 [-0.059, 0.313] and with the naive second rater at 0.169 [-0.029, 0.391]; both intervals span zero. The cross-family corroboration the design relies on is thus between one judge with modest human agreement (0.337 and 0.426) and one with none established. Three facts compound this: on the 28 images where human scores exist the two judges agree with each other at only 0.271 [0.056, 0.448], far below the 0.562 and 0.440 the gate is read on; their per-field agreement on distortion is 0.069, yet distortion contributes a quarter of the composite and carries the strongest SDXL association (-0.486); and SD 3.5 clears the 0.4 gate only because ten empty-prompt baselines are included. The 0.271-to-0.562 gap is likeliest explained by full-corpus agreement being inflated by the extreme contrast between g = 1 and high-guidance images rather than by fine-grained rubric agreement; a kappa within guidance bins would test that, and with an expanded human subset (the authors' own future-work item 2) would make the endpoint trustworthy.

  3. The nearest prior literature is absent from Section 1.1. Related work covers guidance and psychedelic neuroscience, but not fine-grained artifact assessment of generated images by vision-language models, which is where the rubric contribution actually sits. At minimum: J. Wang, J. Hu, X. Ma, H. Ma, Y. Zeng and X. Wei, "MagicMirror: A Large-Scale Dataset and Benchmark for Fine-Grained Artifacts Assessment in Text-to-Image Generation", arXiv:2509.10260, 2025, which builds an artifact taxonomy, 340K annotated images and a VLM assessor; and N. Kamali, K. Nakamura, A. Kumar, A. Chatzimparmpas, J. Hullman and M. Groh, "Characterizing Photorealism and Artifacts in Diffusion Model-Generated Images", CHI 2025, doi:10.1145/3706598.3713962, a human-validated artifact taxonomy. The novelty claim cannot stand until these are engaged, and the comparison should help: those taxonomies are not doseable, not pre-registered and not audited for judge validity.

Minor Comments

  1. The 45% rate in Table 8 comes from prompts containing literal lattices, as the authors' own notes (brick wall, window mullions, tiles) and the portrait prompt's 0 of 8 show, so the 20% ceiling was miscalibrated against this control set and the Exp 01 reclassification is overly conservative.
  2. The rubric names only under-conditioning phenomena, leaving high-guidance failure (oversaturation, waxiness, [8]) largely unscorable, which Table 9 reflects in SD 3.5's composite rising after g = 7 while Q falls at g = 15.
  3. The prompt-generality gate counts only the sign of a Spearman, so SD 3.5 passes 5/6 with the forest prompt at rho -0.02 - and that prompt is the designed control, pre-registered to behave differently yet counted in the tally (Section 3.1).
  4. CLIP-IQA and the aesthetic predictor correlate at Spearman -0.155 on SDXL and +0.170 on SD 3.5 (Section 5), so Q is not a coherent construct; promote the per-component sensitivity into Table 4.
  5. Qwen3-VL-32B was selected on the 28-image gradedness probe and then evaluated for human agreement on those same images (Sections 2.5, 3.4); state the reuse or hold out a disjoint set.
  6. The slope gate is adjudicated on the point estimate against -0.20 while requiring only that the interval exclude zero (Table 3); a non-inferiority formulation would have avoided the "neither shown nor ruled out" verdict.
  7. Report whether dropping the seed random effect, whose variance is estimated at zero, changes the SD 3.5 slope and interval (Sections 3.1, 3.3).
  8. Section 2.8 claims every number regenerates with one command, but Section 6 reports the corrected reports "have not yet been re-verified from a clean public checkout"; reconcile these.
  9. The Exp 02 gates are enumerated differently in Sections 2.6 and 3.5; use one list.
  10. Exp 01 used Claude Sonnet 4.6 and Exp 03 Claude Sonnet 5 with the registered calibration between them not run (Section 5), so note that the two are not on a comparable scale.
  11. No alternative degradation (fewer steps, injected noise, prompt ablation) was scored on the same rubric, so "assay" overstates what is shown about guidance-specificity.
  12. Report the compute and API cost of the grid, since Section 4.2 sells the procedure as something another group can run.

Author response

I agree with the report's positioning: the durable contribution is the instrument (the judge audit, the gradedness screen and the public corpus), and the next version will lead with it rather than with the dose-response. I ran the checks this report asks for on the public images on 2026-10-22, pre-specified before running; the script and output are in the public repository. The first changes how the SDXL result should be read.

Major 1, prompt adherence. Correct, and the most consequential point in any of the three reports. I computed CLIP ViT-L/14 image-text similarity against each registered prompt. It rises with guidance (Spearman +0.34 SDXL, +0.31 SD 3.5). The pooled partial correlation barely moves (-0.556 and -0.240 controlling similarity; -0.529 and -0.238 with both quality proxies added). Inside the mixed model, where the estimate is within prompt, it does move: the guidance slope is -0.248 [-0.312, -0.183] on SDXL and -0.082 [-0.148, -0.017] on SD 3.5 with similarity as a covariate, and -0.201 [-0.276, -0.127] and -0.082 [-0.150, -0.014] with similarity, CLIP-IQA and the aesthetic score together. So a within-prompt association survives on both checkpoints with intervals away from zero, but on SDXL it sits on the registered -0.2 bar rather than well past it, and on SD 3.5 more than half of it is shared with prompt adherence. One caveat: breakdown itself lowers image-text similarity, so this adjustment partly removes the outcome and is a lower bound, not a clean separation. The next version will report this in the main results and say that the composite is only partly separable from adherence.

Major 2, judge agreement. The suspicion is confirmed. Composite kappa on conditioned images within guidance bins: low (g 1-2) 0.550 SDXL and 0.419 SD 3.5; mid (g 3-5) 0.396 and 0.172; high (g 7-15) 0.220 and 0.190. The judges agree at the gate level where breakdown is common and weakly where it is rare, so the pooled 0.542 and 0.394 are carried by the low-guidance images. Together with Qwen3-VL-32B's unestablished human validity, this means the instrument gate licenses the low-guidance contrast more than a graded dose-response. The binned kappas will go next to the pooled ones, and a larger human panel stays the first item of the next study.

Major 3, literature. Agreed. MagicMirror (arXiv:2509.10260) and Kamali et al. (CHI 2025) will be engaged in Section 1.1, and the novelty claim restated against them: their taxonomies are larger and human-annotated; what this paper adds is a doseable perturbation, pre-registration and a judge-validity audit.

Minor comments. (3) and (5) are answered in my reply to the Reviewer3 report: on the five test prompts the tally is 5/5 and 4/5, and dropping the 28 screening images changes no slope or kappa beyond the second decimal; the reuse will be stated. (7) Dropping the seed random effect leaves both slopes unchanged (SDXL -0.340 [-0.402, -0.278], SD 3.5 -0.182 [-0.248, -0.116]). (4) The per-component adjustments will go into Table 4. (1) Agreed that the 20% ceiling was set without regard to prompts containing literal lattices; the Exp 01 reclassification follows the registered rule and stays, with that context stated. (2) and (11) Agreed; the rubric scores under-conditioning only, and without another degradation scored on it, "assay" is claimed for guidance and not for specificity. (6) Agreed; a non-inferiority formulation is what I would register now. (8), (9), (10) and (12) will be fixed: the clean-checkout regeneration claim reconciled, one list of Exp 02 gates, the Sonnet 4.6 and Sonnet 5 scales marked as not comparable, and compute and API cost reported.

Youssef Hassan