XSci

An Absolute Acoustic Readout of Plate Wave Speed for Bullion Authentication, Using a Measured Fill-Factor Correction for Struck Coins

Sylvia Dong, Takyiu Liu

Submitted by Sylvia Dong

Published October 24, 2026 · Version v1, October 24, 2026 · DOI 10.66977/xsci.2610.002n

Audio and Speech Processing, Classical Physics

Abstract

Acoustic "ping" testing of bullion is empirical: it compares a coin's ringing frequency with frequencies recorded for the same coin type, so it cannot assess a specimen absent from the reference library. This work replaces the comparison with an absolute measurement, computed from the measured resonance and geometry through a physical model rather than retrieved from a library. Free-plate flexural resonance is calibrated on five machined aluminium discs (a/t=2.58a/t=2.58--10.7510.75), recovering an empirical finite-thickness coefficient
β=0.895±0.047\beta=0.895\pm0.047 that reduces the worst-case departure from thin-plate theory from 8.9% to 0.75%. A fill factor, the ratio of a coin's displaced volume to its nominal cylinder, supplies the effective thickness that relief hides from calipers, extending the calibration to struck coins. The readout is the plate wave speed cp=E/ρ(1−ν2)c_{p}=\sqrt{E/\rho(1-\nu^{2})}, a material constant, conditioned on an assumed Poisson's ratio. On six struck 0.999 copper rounds not used in the calibration it recovers a Young's modulus of 119.1±6.7119.1\pm6.7 GPa, inside the accepted 110 to 128 GPa. The recovered wave speeds form distinct observed groups across the measured specimens, with the strongest independent validation provided by these copper rounds. The (3,0)/(2,0)(3,0)/(2,0) mode ratio falls below its thin-plate value in thirteen of sixteen specimens (one-sided sign test, p=0.011p=0.011), as finite-thickness theory predicts. Weighing displaced mass to 0.1 mg rather than 0.1 g cut per-specimen volume uncertainty from 1.6% to 30% to 0.5% to 2.6% and shrank an apparent 11% design-dependent bias to a 4.7% residual on one deeply relieved silver design. The readout is now limited by tabulated elastic constants and the assumed Poisson's ratio, not by the acoustics, which are reproducible to 0.15%.

View PDF

Review reports

Reviewer3 (AI review)

October 24, 2026

AI Review (reviewer3.com)

Comments (9)

1. Section IV-B and Appendix B disagree on refitted calibration values — Editorial

. Refitting from each of the two independent output files that cover this session returns β = 0 . 895 and 0 . 897 and C = 1292 . 2 and 1 292.6 Hz m—a spread in β of one-twentieth of its own uncertainty and in C of 0.03 %—with worst-case residuals of 0.75 % and 0.83 %.

Section IV-B states that refitting the aluminium calibration from the two per-tap output files covering the session "returns \beta = 0.895 and 0.897 and C = 1292.2 and 1 292.6 Hz m—a spread in \beta of one-twentieth of its own uncertainty and in C of 0.03 %." However, Appendix B (Table X and accompanying text) reports the joint fit on the earlier file as \beta = 0.898 \pm 0.048 (or 0.895 \pm 0.047 for the lower cluster) rather than 0.897, and states in prose that fitting from either file "changes C by less than 0.02 %" (with Table X listing C = 1292.2, 1292.4, and 1292.3 Hz m at fixed \beta = 0.895).

2. Table IV 0.1 g volume uncertainty range contradicts main text — Editorial

In the Abstract, Section V-B, and Section VI, the displaced-volume uncertainty at 0.1 g resolution is stated as "1.6 % to 30 %" per specimen. However, Table IV lists the contribution for "V (0.1 g)" as "1.6–6 %" without noting that this narrower range applies only to the subset of three larger specimens (R6, R10, R17) that were not remeasured at 0.1 mg, rather than across the struck coins as stated in the Table IV caption.

3. Inconsistent metrics and values for residual silver design bias — Editorial

The manuscript conflates two different definitions of the design-dependent bias on the deeply relieved silver rounds—the worst single-specimen deviation from handbook (-11.0 % at 0.1 g to -3.7 % at 0.1 mg) and the difference between the two silver design-family group means (10.1 % at 0.1 g, from -7.4 % vs. +2.7 %, to 4.7 % at 0.1 mg, from -2.0 % vs. +2.7 %)—resulting in conflicting statements across sections. The Abstract states that remeasurement "shrank an apparent 11 % design-dependent bias to a 4.7 % residual on one deeply relieved silver design" (comparing the 0.1 g worst single-specimen deficit of 11.0 % against the 0.1 mg between-group difference of 4.7 %). In contrast, Section V-A states that "the largest single deficit falls from 11.0 % to 3.7 %" and that on the deeply relieved design the readout "reads 2.0 % low on average and at most 3.7 %," while Section V-B states that "the apparent design bias shrinks from 11 % to under 4 %."

4. Ambiguous optimization objective in calibration fits — Major

Fitting the uncorrected thin-plate prediction f 1 = C ( t/a 2 ) through the origin gives C = 1 182 . 8 Hz m with R 2 = PREPRINT 7 0 . 99530 . That would ordinarily be reported as confirmation. It is not: ordered by increasing t/a the residuals run +8 . 9 , +5 . 6 , +3 . 5 , +1 . 6 and −3.6 %, thin discs ringing high and thick discs low, monotonically with a single crossover (Fig. 3).

The authors report fitting the uncorrected thin-plate model f1 = C(t/a^2) to obtain C = 1182.8 Hz m and the rational finite-thickness model (Eq. 3) to obtain C = 1292.2 Hz m and beta = 0.895, quoting percentage residuals on f1 relative to the fitted prediction (+8.9%, +5.6%, +3.5%, +1.6%, -3.6% for the uncorrected model, and 0.41% RMS for the corrected model). However, across the five calibration discs, f1 spans a factor of seven (from 3525.1 Hz on Al4 to 25,953.9 Hz on Al2). In an unweighted nonlinear least-squares fit of absolute frequency f1, the sum of squared residuals in Hz is heavily dominated by the two highest-frequency discs (Al1 and Al2), whereas fitting relative residuals (or equivalently fitting C_i = f1 * a^2 / t) weights all aspect ratios equally. Indeed, evaluating the data in Table VI against C = 1182.8 Hz m yields percentage departures (f1 - f_pred)/f_pred of +8.18%, +5.33%, +3.40%, +1.55%, and -3.77%, whereas the inverse ratios (f_pred - f1)/f1 are -8.91%, -5.63%, -3.52%, -1.57%, and +3.64%—matching the magnitudes reported in the text with opposite signs. The authors should explicitly state the objective function minimized in both calibration fits (absolute frequency residuals vs. relative frequency residuals) and clarify the exact sign and denominator convention used for 'departure from prediction (%)'.

5. Omission of raw displaced-mass measurements from specimen inventory — Major

Table VI lists every specimen with its measured geometry,

The paper's central metrology conclusion is that displaced volume V—obtained from displaced mass m_disp in distilled water—is the dominant source of instrumental uncertainty, and that remeasuring m_disp on a 0.1 mg balance rather than a 0.1 g balance transforms the results (Section III-B, Section V-A). However, Table VI (the complete specimen inventory) omits both the measured displaced mass m_disp (or volume V) and the per-specimen volume repeatability scatter, and it does not list the 0.1 g vs. 0.1 mg readings that underpin Figure 9 and the before-and-after comparisons in Section V-A. While V can be back-calculated approximately from d, t, and phi (or m and rho) up to rounding in those columns, providing the actual measured m_disp values and their standard deviations (at both 0.1 g and 0.1 mg where measured) in Table VI or an appendix table would make the primary metrological data directly verifiable.

6. Non-independent design replicates in binomial sign test — Minor

the geometry is known. Thirteen lie below their material’s Kirchhoff value, which is the predicted direction (one-sided binomial sign test, p = 0 . 011 ; the statistical units are the sixteen specimens, each represented by its mean ratio, not the individual taps). The predicted

To test whether the (3,0)/(2,0) modal frequency ratio falls below the Kirchhoff thin-plate limit, the authors apply a one-sided binomial sign test across 16 specimens (p = 0.011) and across the 14 non-calibration specimens (p = 0.029), treating each specimen as an independent statistical unit. However, as established in Sections IV-E and V-A, the modal ratio is strongly perturbed by coin relief geometry, and the 14 struck specimens are not independent designs: five of the silver rounds (R11–R14, R17) share a single commemorative relief design from one mint, and several copper rounds (such as R1 and R2, and R3–R5) share identical designs and dimensions. Because relief geometry systematically shifts modal frequencies and ratios within a design family, replicates of the same relief design violate the independence assumption of the binomial test. The authors should either repeat the sign test after aggregating specimens by distinct design family or explicitly note that design clustering among the 14 struck coins reduces the effective degrees of freedom of the binomial test.

7. Propagation of correlated volume error into recovered Young's modulus — Major

This work therefore inverts the comparison. Rather than asking whether the recovered c p matches a selected reference, it recovers the Young’s modulus implied by the measurement, E = c 2 p ρ (1 − ν 2 ) with the specimen’s own measured density, and asks whether that value falls inside the accepted range for the claimed material. This is what ASTM E1876 does with

The authors invert the comparison against handbook elastic constants by computing the recovered Young's modulus E = cp,eff^2 * rho * (1 - nu^2) using each specimen's own measured Archimedes density rho = m/V, and classify group means based on whether E falls inside or within one standard error of the accepted range (Table V). However, because cp,eff is roughly proportional to V^(-1) (with logarithmic sensitivity (q - 1)/(1 + q) ≈ -0.96 to -1.00) and rho = m/V is proportional to V^(-1), the recovered modulus E = cp,eff^2 * rho * (1 - nu^2) scales approximately as V^(-3) (and as a^8 in radius). While the authors note in Section III-B that a hypothetical 0.65% volume bias shifts E by ~2% (3 * 0.65%), Table IV and Section III-C only present the sensitivity budget for cp,eff, and the text does not state whether the group standard errors used to classify 'edge' groups in Table V are computed purely from inter-specimen scatter or include the correlated V^(-3) and a^8 measurement uncertainties (which for R10, R17, and C1–C4 are substantial). The authors should explicitly state the logarithmic sensitivities of E to V (approx. -3) and a (approx. +8) and clarify whether the standard errors used for the 'edge' classifications in Table V reflect inter-specimen SD/sqrt(n) alone or incorporate the propagated measurement uncertainties.

8. Systematic negative shift between sessions treated as random RMS scatter — Minor

0.084 %). Between-session reproducibility is the binding fig- ure: four aluminium discs remounted and re-measured on a separate day shifted by − 0 . 026 , − 0 . 133 , − 0 . 159 and −0.222 %—all in the same direction, RMS 0.152 %. A stronger statement follows from fitting the calibration constant indepen- dently from each session at fixed

When assessing between-session reproducibility on the four remounted aluminium discs, the authors observe that all four frequency shifts are negative (-0.026%, -0.133%, -0.159%, and -0.222%) and summarize this as an RMS reproducibility of 0.152%. Moreover, when fitting C at fixed beta = 0.895 on those same four discs, the two sessions agree to 0.07% (1290.50 vs. 1289.66 Hz m), which is smaller than the shift of three of the four individual discs. A uniform one-sided shift across all four specimens suggests a session-level systematic offset (such as ambient temperature affecting the elastic modulus of aluminium at ~ -0.025%/K or recorder clock drift) or a discrepancy between which discs dominate the unweighted fit for C, rather than purely random mounting scatter. The authors should clarify why the fitted C shifts by only 0.07% when the mean relative shift across the four discs is -0.135%, and briefly discuss whether environmental temperature or mounting tension accounts for the unidirectional drift.

9. Inconsistent volume uncertainty bounds for 0.1 g resolution — Major

Quantity: V (0.1 g) | Source: division | Sens.: -0.96 to -1 | Contrib.: 1.6–6 %

There is a discrepancy between the text and Table IV regarding the per-specimen volume uncertainty at 0.1 g balance resolution. In the Abstract, Section V-B (p. 13), and Section VI (p. 15), the authors state that on displaced masses of 0.3 g to 6.4 g measured to 0.1 g, the volume uncertainty was '1.6 % to 30 %' per specimen (since 0.1 g / 0.32 g ≈ 31% for the smallest coin R11, and 0.1 g / 6.2 g ≈ 1.6% for R6/R17). However, Table IV ('Contributions to the uncertainty in cp,eff', p. 5) lists the contribution of 'V (0.1 g)' as '1.6–6 %'. It appears '6 %' in Table IV was either a typographical error for '30 %' or was restricted only to the subset of larger coins (R6, R10, R17) that were never remeasured at 0.1 mg (though R10 has m_disp ≈ 1.67 g, giving 6.0%). The authors should reconcile Table IV with the 1.6%–30% range quoted throughout the rest of the paper, or clarify in the Table IV caption that the 1.6%–6% row applies only to the three specimens retained at 0.1 g in the final production table.

xPeerd (AI review)

October 24, 2026

AI Review (xPeerd — DAReview)

Summary

This preprint proposes an acoustic method for bullion authentication that replaces coin-specific frequency matching with an “absolute” readout of plate wave speed derived from resonance and geometry, using a fill-factor correction to estimate effective thickness in struck coins. The manuscript’s main strengths are its clear problem framing, strong effort to separate what is demonstrated from what is only inferred, explicit uncertainty discussion, and an independent validation set of six struck copper rounds not used for calibration. The authors report that calibration on five aluminium discs yields an empirical finite-thickness coefficient β = 0.895 ± 0.047, and that the copper validation recovers a mean Young’s modulus of 119.1 ± 6.7 GPa within accepted literature ranges. The paper also appropriately acknowledges important scope limits, including dependence on assumed Poisson’s ratio, lack of blind classification, and absence of acoustic measurements on tungsten specimens.

The main weaknesses are that the strongest practical claim—bulk discrimination where density can fail—is not demonstrated on tungsten, design-relief effects remain only partly resolved, some key specimen identities remain unverified, and several uncertainty terms are excluded from the per-specimen error bars. The work is methodologically promising and more rigorous than typical empirical “ping tests,” but some conclusions should be narrowed further to match what is directly validated.

Potential Major Revisions

  1. The central “absolute measurement” claim should be toned down further in the title, abstract, and conclusion.

The manuscript is careful in later sections to define “absolute” narrowly: “computed from the measured resonance and geometry through a physical model rather than retrieved from a coin-specific frequency library” and “it does not mean an assumption-free determination of intrinsic material properties” . However, the title and abstract foreground “An Absolute Acoustic Readout” and “This work replaces the comparison with an absolute measurement” in a way that may still overstate the epistemic status of the output given the admitted dependence on assumed Poisson’s ratio and model transfer assumptions.

This matters because the paper itself shows that λ² depends on ν and that “the readout is therefore a ν-conditioned estimate of cp” with a systematic bounded at “±3 % across ν = 0.28–0.37.” It also states that using a single λ² across materials introduces “a systematic error of up to 2.4 %, largest on silver.” The title and abstract should therefore reflect that the method is absolute only relative to a model-conditioned reconstruction, not a direct intrinsic-material measurement. As written, the current framing risks sounding stronger than the evidence supports.

  1. The most practically important counterfeit case is predicted rather than empirically demonstrated.

The introduction rightly motivates density-matched substitution as the hard case, emphasizing that “Gold and tungsten differ by 0.3 % in density, yet the elastic constants of Table II put their plate wave speeds at 2 240 m/s and 4 810 m/s.” The conclusion then highlights tungsten as the extension “that would most improve the measurement now.”

But the paper also concedes that “neither tungsten specimen produced a reproducibly detectable resonance under the conditions used,” and that “the acoustic rejection is predicted, not demonstrated.” Likewise, Figure 5 is explicitly described as showing a separation that is “predicted, not measured: no acoustic reading was obtained from either tungsten specimen.”

This is a substantive limitation, not a minor caveat. Since the work’s practical significance rests heavily on overcoming the density limitation of bullion testing, the manuscript should not present the tungsten case as a near-validated success. It should instead distinguish sharply between:

  • demonstrated separation on copper, silver, aluminium, and inferred steel-/brass-like rounds;
  • predicted but untested rejection of tungsten by the acoustic axis.

A stronger revision would restructure parts of the abstract and conclusion so that the copper validation is the primary demonstrated result, while tungsten remains a clearly identified hypothesis or future validation target.

  1. Calibration transfer from aluminium to struck coins of different materials is plausible but not independently validated in form.

The method calibrates finite-thickness correction on “five machined aluminium discs” and then transfers that correction to struck coins. The paper is admirably open that the higher-mode ratio validates the need for a finite-thickness correction but “does not independently confirm its form,” and that “a series of machined discs between t/a = 0.1 and 0.2 would” do so.

This is an important methodological gap. The coefficient β is fitted on one material class and geometry family, then applied across other materials and non-uniform relief patterns. The manuscript later states that excluded uncertainty terms include “the error in transferring β from aluminium to other materials.” The conclusion nevertheless presents the corrected readout as operationally robust.

I think the manuscript should more explicitly separate:

  • empirical calibration of β on flat aluminium discs;
  • heuristic/model-based transfer of β to struck, relieved, non-uniform specimens;
  • independent validation only at the level of copper consistency, not direct validation of the correction law itself.

Without this distinction, readers may overinterpret agreement on copper as proving the entire correction architecture rather than showing one successful external consistency check.

  1. Uncertainty presentation remains potentially misleading because displayed error bars are partial.

Table VI explicitly states that the per-specimen uncertainties are “measurement-derived, not total predictive uncertainties” and “exclude Poisson’s-ratio uncertainty for a specimen of unknown material, relief model error, displacement bias beyond the 0.5 % floor and β-transfer error.” Table IV similarly states that only some sources enter the displayed u, and that “A 0.6 % error bar therefore does not mean that the recovered material property is accurate to 0.6 %.”

This caveat is scientifically responsible, but it creates a presentation problem: figures and grouped comparisons may visually suggest a more complete uncertainty characterization than is actually supplied. Since several key conclusions depend on small differences of a few percent—especially the residual design effect and near-edge agreement with accepted material ranges—partial uncertainty bars can easily be overread.

The revision should either:

  • show two uncertainty notions consistently: measurement-derived and broader interpretive/model uncertainty; or
  • relabel figure captions more forcefully and reiterate in Results that non-overlap of point estimates is not equivalent to resolved composition classes.

The manuscript already says “The groups are observed groupings of point estimates, not uncertainty-resolved composition classes.” That caution should be carried into the abstract-level messaging.

  1. The inference regarding unverified “steel-like” and “brass-like” rounds is appropriately cautious but still too prominent relative to evidential strength.

The manuscript states that for C1–C5, “the material column gives the class the measurements are consistent with, not an assayed composition.” It further acknowledges: “The compositions of C1–C5 have not been independently established,” and that confirming them would require “an independent bulk analysis.” Later it emphasizes that the method “cannot exclude a plated or layered construction.”

This is the right caution, but the manuscript still spends substantial space interpreting these rounds compositionally. Given the absence of destructive assay or cross-sectional analysis, these examples should be framed as stress tests of internal consistency, not as quasi-identifications. In particular, statements like “the non-ferromagnetic fifth has properties consistent with a brass-like copper–zinc alloy” are acceptable only if repeatedly paired with the reminder that consistency with a candidate material is not identification.

I recommend demoting these cases from evidentiary pillars to illustrative applications.

  1. The residual design-dependence claim remains underdetermined.

Section V-A is one of the strongest parts of the paper because it narrows the claim and quantifies the remaining effect. The authors write that at 0.1 mg resolution, the deep-relief family averages −2.0 % and the others +2.7 %, with a 4.7 % difference at p = 0.033, but that among the six measured at fine resolution the effect is 3.6 % and “not significant (p = 0.19).” They also admit that affected specimens share one design and that “design and die [are] confounded.”

That means the mechanism is not established, only suggested. Yet the abstract’s statement that improved balance “shrank an apparent 11 % design-dependent bias to a 4.7 % residual on one deeply relieved silver design” can still sound more definitive than warranted. I would revise this to stress that the residual effect is tentative, specimen-family-specific, and not yet disentangled from die-specific or model-structure effects.

  1. The detection pipeline has an important abstention mode that should be emphasized more clearly in the practical claims.

The manuscript states that low-Q specimens may simply produce “no acoustic reading at all rather than a wrong one,” and that at sufficiently low damping the method becomes effectively blind. The injection analysis provides an empirical threshold, noting no detections at Q ≤ 100–150 depending on frequency, while all reported specimens are above that limit.

This is an important operational property. A counterfeit made of suitably lossy material could defeat the acoustic channel by inducing abstention rather than mimicry. The paper does note this, but the practical framing should treat “abstains/no reproducible resonance” as an explicit outcome class in the proposed workflow, not merely a limitation note.

  1. Some reproducibility-sensitive aspects of the protocol remain manual or ad hoc.

The manuscript is transparent that “Excitation was manual throughout” and that some estimator choices, such as the detection boundary, were “established empirically rather than derived.” Likewise, one specimen required a “lowered-floor re-run” because the 1 kHz search floor misassigned the fundamental.

These choices are not fatal for a proof-of-concept, especially given the reported between-session reproducibility of about 0.15 %. However, they do limit external reproducibility and deployment readiness. The revision should provide either a more formal pre-registered rule set or a compact reproducibility appendix with exact decision logic, exception handling, and parameter sensitivity.

Anti-fraud / coherence check

I do not see strong paper-mill or fabrication signals. The manuscript is internally coherent, numerically self-aware, and unusually explicit about its own limitations. It repeatedly marks where evidence is direct, inferred, conditional, or merely predicted, which argues against a fraudulent presentation style. Examples include the statements that tungsten rejection is “predicted, not demonstrated,” that candidate materials for unverified rounds are “not an identification,” and that displayed uncertainties are not total predictive uncertainties.

That said, one caution is warranted: because the manuscript is a preprint making a practically appealing authentication claim, any public-facing language that overstates the tungsten case or the meaning of “absolute” could be misread as stronger validation than the evidence supports. This is a framing risk, not evidence of misconduct.

Potential Minor Revisions

  1. Typographic and wording issues
  • In the abstract, “Weighing displaced mass to 0.1 mg rather than 0.1 g cut per-specimen volume uncertainty from 1.6 % to 30 % to 0.5 % to 2.6 %” is awkwardly phrased and potentially confusing because it presents two ranges without clear mapping. It should be rewritten, for example, as “from 1.6–30% to 0.5–2.6%.”
  • The same awkward range expression recurs in the conclusion: “per-specimen uncertainty fell from 1.6 % to 30 % to 0.5 % to 2.6 %.” This should likewise be standardized.
  • Several places contain OCR/hyphenation artifacts in the extracted text, such as “vibra￾tion,” “con￾sequence,” and “mea￾surement.” If these are present in the manuscript PDF rather than only in extraction, they should be corrected before submission. They appear in the keyword list and multiple sections.
  • In Section V-E, “the method reads them” is slightly informal for journal prose. A more precise alternative would be “the method yields consistent estimates for them” or similar.
  • In Section IV-F, “the effect is diagnosed above rather than hidden” is rhetorically strong and could be simplified to a more neutral statement.
  1. Formatting and presentation issues
  • Tables V and VI are information-rich, but the distinction between measured quantities, inferred classes, and calibration materials should be visually stronger. For example, use footnote markers more prominently or add a dedicated “status” column: assayed / inferred / calibration-only.
  • Figures 4–6 appear central to the paper’s claims. Because several conclusions hinge on the difference between point-estimate grouping and uncertainty-resolved separation, those figures should visually emphasize this distinction in the legend or caption.
  • The limitation list is excellent, but it appears late. Consider moving a compact “scope of claims” paragraph into the end of the Introduction or beginning of the Discussion.
  • The manuscript uses “Preprint, October 2026” and arXiv-style formatting. Before journal submission, ensure conformity with target venue style, especially for author affiliations, contribution statement, appendix layout, and table capitalization.
  1. AI content analysis for this post-2021 manuscript

Estimated percentage of AI-generated content: low, approximately 5–15%.

Rationale:

  • The manuscript has a highly disciplined, technical, and self-corrective style with repeated narrowing of claims, explicit admission of limitations, and numerically specific caveats. This is more characteristic of careful domain-authored scientific prose than generic AI-generated exposition.
  • The argumentation is consistent across introduction, method, results, and limitations, with no obvious semantic drift or fabricated citation behavior in the retrieved sections.
  • There are no strong signs of AI-style padding, generic transition inflation, or repetitive high-level claims unsupported by local detail.

Highlighted potentially AI-like sections:

  • I do not identify any section as obviously AI-generated from the retrieved text alone.
  • Some polished rhetorical contrasts, such as “XRF is a surface technique being asked a bulk question” and “A frequency is not a property of silver—it is a property of this piece of silver,” are memorable and stylized, but they are field-appropriate and supported by subsequent technical exposition rather than empty flourish.
  • The limitations section is unusually systematic and could superficially resemble assisted drafting, but its specificity argues in favor of genuine authorial control.

Assessed epistemic impact:

  • Even if limited AI assistance were used for copyediting or prose polishing, I do not see evidence in the manuscript excerpts that this undermines the epistemic contribution.
  • The main epistemic risks arise from validation scope, transfer assumptions, and uncertainty framing, not from suspected AI authorship.

Recommendations

  1. Revise the framing so the strongest demonstrated contribution is clear: the paper successfully shows a model-based acoustic readout that calibrates on aluminium and externally validates on six copper rounds, while tungsten rejection remains a theoretically motivated but unverified case.

  2. Modify the title, abstract, and conclusion to reduce possible overreading of “absolute.” Make the ν-conditioned and model-conditioned nature of the readout explicit at first mention, not only later in the manuscript.

  3. Distinguish more sharply between measured, inferred, and predicted results:

  • measured: aluminium calibration, copper validation, silver and unverified-round observations;
  • inferred: candidate composition classes for C1–C5;
  • predicted: tungsten acoustic rejection.
  1. Expand uncertainty communication. Either provide total interpretive uncertainty bands for headline claims or add a dedicated summary paragraph explaining exactly what the plotted error bars do and do not mean.

  2. Reframe the design-relief result as a tentative residual effect tied to one design family, not a settled correction problem.

  3. If feasible before submission, add one of the following:

  • an excitable tungsten or tungsten-alloy specimen with measurable resonance;
  • a blind classification trial;
  • a second deep-relief design from another mint;
  • independent bulk composition verification for at least some unverified rounds. These would each materially strengthen the manuscript’s practical credibility.
  1. Provide a compact reproducibility package in the paper or supplement: exact signal-processing parameters, acceptance/rejection thresholds, remount protocol, exception handling for low-frequency specimens, and code availability statement. The current methods are promising, but a more formal reproducibility scaffold would increase trust and uptake.

Overall, I judge the manuscript to be technically thoughtful, substantially more rigorous than typical empirical acoustic bullion tests, and potentially publishable after major revision. Its strongest asset is that it already contains many of the caveats needed for a credible paper; the main task is to align the headline claims strictly with what the data directly establish.

XSci (AI review)

October 24, 2026

Summary

Acoustic "ping" testing of bullion compares a coin's ringing frequency with frequencies recorded for the same coin type, so it cannot assess a specimen absent from the library. The authors replace that comparison with a physical-model inversion returning the plate wave speed cpc_p , conditioned on an assumed Poisson's ratio. Two obstacles are addressed: a finite-thickness coefficient β=0.895±0.047\beta=0.895\pm0.047 , fitted on five machined aluminium discs, which reduces the worst-case thin-plate residual from 8.9 % to 0.75 %; and a fill factor φ=V/πa2t\varphi=V/\pi a^2 t from liquid displacement, supplying the effective thickness relief hides from calipers. On six struck 0.999 copper rounds held out of the calibration the method recovers E=119.1±6.7E=119.1\pm6.7 GPa against an accepted 110–128 GPa, and weighing displaced mass to 0.1 mg cuts the volume term from 1.6–30 % to 0.5–2.6 %.

Contribution and Significance

The core contribution is Eq. (4): an Archimedes volume divided by the nominal disc area gives a volume-equivalent thickness, enough to put a struck coin into a free-plate resonance inversion that otherwise demands uniform, caliper-measurable geometry. This removes the coin-type library, with a balance and a beaker rather than an instrument. The second contribution, less advertised, is the error analysis: the authors derive sensitivity coefficients from their own estimator (Eq. 6), notice that radius enters at +3.9+3.9 to +4.0+4.0 rather than +1+1 because it also sits inside tefft_{\mathrm{eff}} , and use that ordering to predict that a finer balance rather than better acoustics would improve the measurement. They tested the prediction and it held (Section V-B).

The advance is narrower than the framing suggests. Dao et al. [2] and the commercial tool [3] are described accurately, but model-based coin acoustics is not new: Manas (Eur. J. Phys. 36(4), 045012, 2015) already applies Kirchhoff theory to coins for counterfeit detection, and ASTM E1876 [4] supplies the inversion. What is new is the volume-equivalent thickness for relieved specimens and the metrology around it, not computing rather than comparing. This is a careful measurement protocol, not the authentication capability the title implies.

Strengths

  • The uncertainty budget (Eq. 6, Table IV) is sensitivity-weighted and made a prediction that was then tested: at 0.1 mg the fine-silver density spread collapses from 9488–10814 kg/m³ to 10530–10579, removing a physically impossible reading for a 0.999 silver round.
  • The copper validation set is genuinely held out: six struck rounds spanning 32.60–47.00 mm at φ\varphi = 0.776–0.810 recover E=119.1±6.7E=119.1\pm6.7 GPa (Table V).
  • Section IV-E gives an independent check through a quantity free of EE , ρ\rho , aa and tt : the (3,0)/(2,0) ratio falls below its Kirchhoff value in 13 of 16 specimens ( pp = 0.011), and 11 of 14 with the calibration discs removed.
  • Awkward results are quantified, not buried: the sterling disc's 887 Hz fundamental, misassigned by the 1 kHz floor and diagnosed from its own mode ratio of 2.353 against a predicted 2.334 (Section IV-F); the tungsten non-detections bounded by an injection test (Section IV-G).
  • The free-plate solver is validated against both of Leissa's tables to 0.04 % and 0.09 % (Table IX), including the finding that his Table 2.5, headed ν\nu = 0.33, is in fact at 1/3.

Recommendation

Major Revision for IEEE Transactions on Instrumentation and Measurement.

The measurement claim is sound and the internal arithmetic reproduces everywhere I checked it. But the validation supporting the central correction is against handbook intervals too wide to establish the accuracy the stated application needs, the dominant uncertainty term rests on a floor the authors themselves call a judgement, and the authentication framing is not what the paper demonstrates. None is fatal, and the work that would close them lies within the manuscript's own approach.

Major Concerns

  1. The validation establishes consistency, not accuracy at the level the application needs (Section IV-C, Table V, Fig. 6). The copper test asks whether the recovered modulus falls inside 110–128 GPa, a 15 % interval corresponding to cpc_p = 3726–4019 m/s by the authors' own Table II. A method carrying a 7 % systematic in modulus — under 4 % in cpc_p — would still pass, and Section V-A shows a design-dependent systematic of a few per cent does exist. The paper therefore shows that the fill factor removes the ~22 % error caliper thickness would introduce at φ\varphi = 0.78, but it does not bound the residual accuracy of tefft_{\mathrm{eff}} , which is what an authentication readout needs. No specimen has independently determined elastic constants: aluminium is the calibration material, the sterling disc is one specimen at uu = 6.1 %, and the tungsten discs gave no reading. The missing control is within reach: machine plain discs from the same copper and silver stock as the struck rounds, fix EE on a slender bar of that stock by ASTM E1876, and compare. That tests the fill-factor approximation at the per-cent level, without a handbook range.

  2. The authentication claim is not demonstrated, and the one adversarial specimen defeated the acoustic axis rather than the reverse (title, abstract, Sections IV-G, V-D, V-F). The decision rule of Section IV-G is magnet plus Archimedes density, and Section V-D declines to threshold cpc_p , so the acoustic readout enters no classification in the paper. The only specimen that falsely passes the density rule is the machined tungsten disc, and neither it nor a second tungsten specimen produced a detectable resonance. The authors are candid about this, but one internal tension is unaddressed: Section IV-G argues the first disc's 19 487 kg/m³ is "compatible with commercially pure tungsten", while the same section's injection test establishes that an in-band mode of QQ above roughly 700–1000 would have been detected — and commercially pure tungsten is not a material of Q<700Q<700 . Either the disc is not what its density suggests, leaving the 9.4 % shortfall of its displaced volume against its nominal cylinder (Fig. 1) unexplained, or the sensitivity bound is optimistic. Resolving this needs an assayed, excitable high-density specimen; failing that, the title and abstract should claim an absolute wave-speed measurement, not authentication.

  3. The dominant uncertainty term has no independent calibration (Section III-B, Table III, Fig. 1). Displaced volume propagates at very nearly unity and sets the budget for every struck specimen, yet the 0.5 % systematic floor is, in the authors' words, "a judgement, not a calibration", interpolated between one machined disc at +0.336 % and the 0.65 % fine-silver density excess. The two 0.1 g discs disagree in sign (+0.039 % and −0.433 %), only one disc was measured at 0.1 mg, and one machined specimen misses its nominal cylinder by 9.4 %. The manuscript states the consequence: if the 0.65 % excess is a common bias, fine silver and the steel-like rounds move from the edge of their accepted ranges to below them. Machined discs of several sizes and densities at 0.1 mg, with thread buoyancy and wetting force characterised directly, would make that floor a measured systematic.

Minor Comments

  1. Sections IV-C and V-D state the silver readings lie "about 60 % below the 4810 m/s" predicted for tungsten; 2790–3040 m/s is 37–42 % below that figure.
  2. Table IV gives the V (0.1 g) contribution as 1.6–6 %, while the abstract, Section III-C and Section V-B give 1.6–30 %; say which population each describes.
  3. The abstract's "apparent 11 % design-dependent bias to a 4.7 % residual" conflates the largest single-specimen deficit (11.0 % → 3.7 %) with the group difference (10.1 % → 4.7 %); Section V-B gives a third rendering.
  4. The copper mean is said to land "within 0.9 % of handbook" (Fig. 4) against a reference value never given; the midpoint of 110–128 GPa gives 0.1 %, and Section II-D rules out comparing to a chosen value inside the range.
  5. Section V-E claims a measurement "obtained from a tap and a microphone", but it also needs the 0.1 mg balance and displacement rig the paper identifies as its binding instrument.
  6. β\beta is two parameters on five points of one aluminium alloy of unrecorded designation; state how much the correction changes each coin result, given q≤0.022q\le0.022 over the struck coins against 0.134 over the discs.
  7. The claim that the first-order coefficient "scales approximately as 2(1+ν)/κ2(1+\nu)/\kappa " (Section IV-B) is asserted with no derivation and no citation.
  8. Published thick-plate solutions make the empirical β\beta avoidable and should be compared against: J. R. Hutchinson, "Vibrations of thick free circular plates, exact versus approximate solutions," J. Appl. Mech., vol. 51, no. 3, pp. 581–585, 1984.
  9. Sections I and V-E omit A. Manas, "The music of gold: can gold counterfeited coins be detected by ear?", Eur. J. Phys., vol. 36, no. 4, 045012, 2015, which models coins with Kirchhoff theory.
  10. Resonant ultrasound spectroscopy, the parent technique for recovering elastic constants from resonances, is absent: A. Migliori and J. L. Sarrao, Resonant Ultrasound Spectroscopy, Wiley, 1997.
  11. The sign test of Section IV-E treats the sixteen specimens as independent, though R1 and R2 share a design and size and five silver specimens share one design.
  12. There is no data or code availability statement, hard to justify when Appendix B shows a changed pipeline default altered the fundamental on 91 of 214 shared taps.