XSci

ConformalShift: Targeted Event Reordering Against Adaptive ECG Monitoring

Arash Vashagh, Yasmin Vashagh

Submitted by Arash Vashagh

Published November 27, 2026 · Version v1, November 27, 2026 · DOI 10.66977/xsci.2611.0058

Machine Learning

Declaration of AI use (v1): OpenAI Codex was used to implement the code and draft some parts of the manuscript and for grammar check.

Abstract

Adaptive conformal prediction can recover clinically important heartbeat
classes missed by a point classifier, but delayed feedback makes its decisions
sensitive to event order. We introduce ConformalShift, a bounded event-reordering
attack that suppresses the ventricular class for rescued events without modifying
ECG waveforms, labels, classifier scores, or the event multiset. ConformalShift
searches for feasible permutations of authentic preceding events that lower the
ventricular threshold before a selected target is evaluated. On disjoint
MIT--BIH confirmation records, the attack suppressed 66.7%66.7\% of eligible
targets for Extra Trees and 60.0%60.0\% for HistGradientBoosting, compared
with random-schedule rates of 4.4%4.4\% and 12.0%12.0\%, respectively.
Transferred configurations also outperformed random scheduling on INCART,
while reducing the displacement budget weakened the attack on both datasets.
These results show that adaptive monitors in healthcare can be compromised
through the timing of authentic information, even when waveforms, labels,
classifier outputs, and event contents remain unchanged.